4 Operation
4.9 PowerPlus
All the cooking zones are equipped with the PowerPlus booster.
When PowerPlus is switched on, the cooking zone selected works at extra high power
for 10minutes. PowerPlus can be used, for instance, to heat a large quantity of water
quickly.
Switching PowerPlus on
Touch PowerPlus « ».
illuminates in the display.
After 10minutes it automatically switches back to power level .
Removing the cookware interrupts PowerPlus. PowerPlus is resumed as soon as
the cookware is returned to the cooking zone.
Ending PowerPlus before time
Touch the desired power level on the slider.
Power management
PowerPlus cannot be used with both
cooking zones of a group (A or B) at the
same time. If PowerPlus is activated with
both cooking zones of a group, then the
power output is reduced for the cooking
zone that was first selected. Cooking
zone 5 can be operated with PowerPlus
independently of groups A and B.
A B
1
2 3
4
5
PowerPlus with cooking zone Group A * PowerPlus with cooking zone Group B *
1 2 3 4
1 3
2 4
*Maximum available power level with cooking zones
If the power level is increased above these levels, PowerPlus switches off.
4.10 Bridging function
The bridging function allows two individual cooking zones lying one behind the other to
be switched on together and to be adjusted together.
Switching the bridging function on
Touch both sliders at the same time.
Illuminates next to the power levels.
Set the required power level.
If, when the bridging function is switched on, a cooking zone is already running,
the power level and operating time of this cooking zone will be taken over for both
zones. If both cooking zones are already running, the operating times are cleared
and flashes in the power level displays.