CLEANING AND MAINTENANCE - 121914779675/A
e
Descaling
Periodically the display will prompt you to
perform the boiler descaling procedure.
1. Touch the CONFIRM button to
confirm.
The appliance suggests the Drain reservoir
function
.
Preliminary operations
In case there is residual water inside the
reservoir:
1. Open the door.
2. Place a jug or a container on the open
door.
3. Pull the loading nozzle out of its housing.
4. Press the START button to start draining
the water into the jug (or container).
Residual water begins to drain into the jug (or
container).
5. Wait for the end of the drain flow.
6. Empty the water in the jug (or container).
7. Touch the CONFIRM button to
continue the function.
Reservoir filling
1. Mix 100 g of citric acid with 650 ml of
water in a jug.
2. Pull the loading nozzle out of its housing.
3. Place the end of the tube at the bottom of
the jug (or container).
4. Touch the START button to start filling
the reservoir of the appliance with the
descaling solution.
5. In the end, shake the loading nozzle to
remove any remaining water.
6. Place the loading nozzle place in its
housing.
7. Remove the jug (or container).
Boiler descaling function
1. Close the door
2. Descaling starts.
At the end of the descaling process the display
shows the request to drain the water softener.
Reservoir draining
1. Open the door
2. Place a jug or a container on the open
door.
3. Pull the loading nozzle out of its housing.
4. Press the START button to start draining
the water softener into the jug (or container).
The presence of scale due to lack of
descaling can compromise correct
operation of the appliance in the long
term.
Descaling is a long process (more than
one hour) that requires the user to be
present in front of the appliance.
We recommend performing descaling
every time this is indicated on the
display in order to keep the boiler in
perfect operating condition.
The descaling process can be skipped
2 consecutive times.
After this, the appliance will not allow
you to run any other function until the
descaling process is performed.
From now on, it will no longer be
possible to cancel the descaling
process.
Do not use lactic acid or other