Kenmore 59672289200 Elite refrigerator

User Manual - Page 19

For 59672289200.

PDF File Manual, 64 pages, Download pdf file

Loading ...
Loading ...
Loading ...
Water Filter Data
System Specification and Performance Data Sheet
® Refrigerator Water Filter Cartridge Model 9005
I Specifications
Service Flow Rate (Maximum) ............................................. 075 GPM (2.83 L/min)
Rated Service Life Model 9005 (Maximum) ......................... 500 gallons/ 1892 liters
Maximum Operating Temperature ........................................ 100 ° F/38 ° C
Minimum Pressure Requirement .......................................... 35 psi/ 138 kPa
Maximum Operating Pressure .............................................. 120 psi/827 kPa
General Use Conditions: Read this Performance Data Sheet and compare the capabilities of this unit with your actual
water treatment needs.
The retractable water filtration system uses a 9005 replacement cartridge (see Sears contact information at the front of your
manual to order). Timely replacement of filter cartridge is essential for performance satisfaction from this filtration system.
Please refer to the applicable section in this Use and Care Guide for general operation, maintenance requirements and
troubleshooting.
This system has been tested according to ANSA1/NSF 42 and 53 for reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentration less
than or equal to the permissible limit for water leaving the system, as specified in ANSI/NSF 42 and 53.
Performance Data*
Influent Challenge Effluent Average % Maximum Min. Required Inlet
Substance Concentration Average Reduction Effluent Reduction pH
Lead 0.15 mg/L +/- 10% 0.001 mg/L 99.33% 0.001 mg/L 0.010 mgiL 6.5
Lead 0.15 mg/L +/- 10% 0.002 mg/L 98.66% 0.003 mg/L 0.010 mglL 8.5
Cyst Minimum 50,000/L lcount/mL 99.99% 3 count/mL >99.95% NA
Turbidity 11+/-1 NTU 0.12 NTU 98.98% 0.18NTU 0.5 NTU NA
Lindane 0.002 mg/L +/- 10% 0.00005 mg/L 92.06% 0.00005 mg/L 0.00002 mg/L NA
Atrazine 0.009 mg/L +/- 10% 0.0002 mg/L 97.93% 0.0006 mg/L 0.003 mg/L NA
Chlorine 2.0 mg/L +/- 10% 0.09 mg/L 95.26% 0.17 mg/L _>75% NA
Particulate** at least 10,000 900 count/mL 99.68% 2400 count/mL _>85% NA
particles/mL
2,4-D 0.210 mg/L +/- 10% 45.45 ug/L 84.42% 100 ug/L 0.0017 mg/L NA
Asbestos 107to l08 fibers/L;fibers greater 0.16 MFL/mL 99.96% 0.16 MFL/mL 99% NA
than 10 micometersin length
Tested usin( a flow rate of 0.75 GPM (2.83 L/min.) and a maximum pressure of 120 psi (827 kPa) under standard
laboratory conditions, however, actual performance may vary. Health Claim Performance tested and certified by NSF
international
** Particle size range classification of test. Particles used were 0.5-1 microns.
Pentapure, Incorporated
1000 Apollo Road
Eagan, Minnesota U.S.A.
EPA EST #35917-MN-1
Tested and Certified by NSF International against ANSI/ NSF Standards
42 & 53 in models WF50-KNI300 and WF50-KWI 500 for the reduction of.
StandardNo. 42 Aesthetic Effects
Taste & Odor Reduction
Chlorine Reduction
Mechanical Filtration Unit
Particlate Reduction Class 1
Standard No. 53: Health Effects
Chemical Reduction Unit
Lead,A_azine,L#_dane& 2,4-DReductiorl
Mechanical Filtration Unit
Cyst, Turbidity,& Asbestos Reduction
]9
DO NOT use this product where water is microbiologically unsafe or of unknown quality without adequate disinfection
before or after the system. System certified for cyst reduction may be used on disinfected water that may contain
filterable cysts.
USE ONLY WITH COLD WATER SUPPLY. CHECK FOR COMPLIANCE WITH THE STATE AND LOCAL LAWS AND REGULATIONS.