23
Device description
www.bora.com
Warming level Symbol Temperature
1 (melting)
,
≈ 42 °C
2 (keeping warm)
:
≈ 74 °C
#
3 (simmering)
≈ 94 °C
Tab. 5.11 Warming levels
The maximum duration for the warming function is
limited to 8 hours.
INFO In practice the temperatures of the warming levels
may vary slightly as they are influenced by the
cookware, the amount of food and the different
heating technologies. The temperatures can also
vary due to the influence of the cooktop extractor.
Bridging function
With the bridging function two cooking zones can be
combined to form one large cooking zone. The power for
the combined zones is then adjusted by a single operating
control. Power adjustment takes place simultaneously
(both cooking zones are operated on the same power
level).
The bridging function is suitable for heating food, e.g. in a
roaster.
Automatic bridging function
If a large enough cooking pot or roaster is placed on the
two cooking zones that are one behind the other, they
will automatically be combined to form one large cooking
zone. It is not necessary to activate the bridging function
manually (see Operation chapter, Customer menu).
Cooking zone timers (automatic cut-off)
The automatic cut-off function automatically switches off
the selected cooking zone once a preset time has lapsed.
The timer function can also be used on several cooking
zones at the same time (multi-timer).
Pause function
With the pause function all cooking zones can be quickly
and easily deactivated temporarily. When the function is
cancelled, operation resumes at the original settings.
The cooking session can be paused for max. 10 minutes.
Once 10 minutes have lapsed, the cooking session is
automatically ended.
Cooktop power setting
When the power setting is activated, maximum cooking
zone power is available for a predefined time.
The available power is focused on the selected
cooking zone, meaning that the max. power of the
second cooking zone on that side is automatically and
temporarily reduced:
If the front cooking zone is operated using the
power setting, a maximum power level of 7 can be
selected in the rear cooking zone.
5.5.2 Cooktop functions
Automatic heat up function
When the automatic heat up function is activated, the
cooking zone works at full power for a certain time and is
then automatically reset to the previously set level.
Power level
(continuous cooking level)
Cooking duration in min:sec
1
00:40
2
01:00
3
02:00
4
03:00
5
04:20
6
07:00
7
02:00
8
03:00
Tab. 5.10 Heating time overview
Pan size recognition
The cooking zone recognises the size of the cookware
automatically and only targets the energy at that area. It
also recognises cookware that is unsuitable or too small
or if there is no cookware present.
A cooking zone is not working if
v
,
/
v
are alternated in the
display. This happens if...
... it is switched on without cookware or with unsuitable
cookware.
... the base diameter of the cookware is too small.
... the cookware is removed from a switched-on cooking
zone.
If no pot is recognised 10 minutes after setting a power
level, the cooking zone will switch off automatically.
Permanent pan size recognition
The cooking zone automatically recognises cookware and
switches the corresponding operating panel on: Manual
activation of the cooking zone is not necessary (see
Operation chapter, User menu).
One-level warming function
On the warming level, meals that have already been
cooked can be kept warm at a lower temperature without
any risk of burning.
The maximum duration for the warming function is
preset to 8 hours.
Variable warming function (3 levels)
Depending on the application or food used, it is
possible to choose from 3 warming levels at different
temperatures: