Operating, Care ana Installation Instructions - Page 8

For WTMC5330US/06. Series: Nexxt 500 plus Series

Loading ...
Loading ...
Loading ...
The installation room must be well
ventilated, otherwise the dryer will
operate below optimum performance.
Do not operate the dryer at
temperatures above 104°F (40°C) or
below 41 °F (5°C). Low temperatures
affect the automatic program sequence
and may prolong the drying times.
The installation surface for the dryer
must be clean, level and firm. Do not
install the appliance on carpets!
Compensate for uneven floors with the
height-adjustable feet.
The size of the installation area
depends on the dimensions of the
dryer. Ensure that there is adequate
room for the swivel range of the door!
If installed in a garage, the dryer
must be installed on a substantial
platform at least 18 inches (46 cm)
above the floor to reduce the
liklihood of igniting flammable
vapors and be located or protected
so it cannot be damaged by a
moving vehicle
Closet
Sides 0" (0 mm)
Top 12" (305 mm)
Rear* 0" (0 mm)
* as closeto wallas gas pipingor ventingor
waterconnectionwill allow.
Important information concerning
minimum distances:
- Depending on the location of the
exhaust air connection, an
additional minimum distance of
51/2inch (14 cm) must be provided
on this side for ducts/brackets (see
page 13).
- Benefits of maintaining greater
distance (clearances) than the
minimum shown include:
reduction of the risk of mold
formation behind the appliance.
reduced noise transmission
facilitation of installation and
service.
more air cools the dryer, keeps
the dryer from overheating, and
improves drying performance.
If the dryer is installed in a small
room, the doors of the room must
be fitted with vents of a specified
minimum size. Refer to the
following figure for additional
information.
Water Connection
Attach the dryer water supply hose to a
cold water faucet (the faucet must be
located within 4 ft (1.2 m) of the water
inlet valve on the back of the dryer).
It is recommended to have a water
supply pressure of 20 - 100 psi (1.37 -
6.89 bar) for best performance.
A "Y" connector is provided along with
a short hose (if needed) in order to
connect it to the cold water faucet.
AQUASTOP ® Hose
Properly secured EXTERNAL hose
connections are the sole
responsibility of the customer. The
manufacturer assumes no
responsibilty or liability for
improperly installed EXTERNAL
hose or other connections.
a
b
C
d
angle
Dimension Weight
27,0" (686mm) 125 Ibs
31,8" (808mm) (56kg)
with
37,2" (945mm) packaging
19,7" (500 mm)/ 143 Ibs
170 180° (64kg)
If installing the dryer in a closet, observe
the minimum distances according to
the following table:
Minimum Installation Clearances
The dryer door is delivered with hinges
on the right.
If the door hinge is to be changed over
to the left see page 13.
The AQUASTOP ® Hose prevents
potential flooding if the hose leaks.
If the hose leaks, a red mark is
displayed and the water inlet is
blocked.
E_ An AQUASTOP ® Hose that has
activated cannot be reset. Contact
Customer Service for a
replacement hose (see page 26).