Operating
Instructions
COOL operation
Press the “MODEbutton until theCOOL
indicator light comes on.
Press the UP and DOWN buttons “+or- to
select your desired room temperature. The
temperature can be set within a range of
17°C~3C/6F~8F.
The fan speed is automatically set to auto.
Use the remote to adjust the fan speed if
desired.
DRY operation
Press the “MODE” button until the “DRY”
indicator light comes on.
While in this mode, you cannot select a
fan speed or adjust the temperature. The
fan motor operates at LOW speed.
Keep windows and doors closed for the
best dehumidifying effect.
FAN operation
Press the “MODE” button until the ”FAN“
indicator light comes on.
Press the “FAN SPEED” button to
choose
the fan speed. The temperature cannot
be adjusted.
Operating Instructions
SLEEP/ECO operation
This feature can be activated from
the remote control ONLY. To activate
SLEEP feature, the set temperature will
increase by 1°C/2°F in 30 minutes. The set
temperature will then increase by another
1°C/2°F after an additional 30 minutes.
This new temperature will be maintained
for 7 hours before it returns to the
originally selected temperature. This ends
the Sleep mode and the unit will continue
to operate as originally programmed.
NOTE
This feature is unavailable in FAN or
DRY mode.
Other Features
NOTE
This feature can be activated from
the remote control ONLY. The remote
control serves as a remote thermostat
allowing for the precise temperature
control at its location.
COMFORTSENSE
Feature (only for some models)
To activate the Temp Sensing feature, point
the remote control towards the unit and
press the Temp Sensing button. The remote
display is actual temperature at its location.
The remote control will send this signal to
the air conditioner every 3 minutes until the
ComfortSense button is pressed again.
If the unit does not receive the Temp
Sensing signal during any 7 minutes interval,
the unit will exit the Temp Sensing mode.
Constant Fan button
Feature (optional) in cooling or Dry mode,
press the button for 3 seconds to turn on or
off the constant fan function. When the
function is turned on, the constant fan light
will illuminate, identifying the fan continuous
run for cooling. When the function is turned
off, the constant fan light will go out,
identifying the fan cycle run with
compressor stop.
AUTO-RESTART
If the unit shuts off unexpectedly due to a
power outage, it will restart with the previous
set function when the power resumes.
WAIT 3 MINUTES BEFORE RESUMING
OPERATION
After the unit has stopped, it cannot be
restarted until 3 minutes time has elapsed.
This is to protect the unit. Operation will
automatically resume after 3 minutes.
AIRFLOW DIRECTION ADJUSTMENT
Adjust the air flow direction manually:
- The louver can be set to the desired
position manually.
- Do not place any heavy objects or
other loads on the louver, doing so will
cause damage to the unit.
- Keep the louver fully opened during
operation.