TROUBLESHOOTING Before calling for service, review this list. It may save you time and expense. This list includes
common occurrences that are not the result of defective workmanship or materials in this
GUIDE
appliance.
PROBLEM CAUSE CORRECTION
BEVERAGE CENTER OPERATION
Beverage center does not
run.
Beverage center runs too
much or too long.
Beverage center is plugged into a circuit
that has a ground fault interrupt.
Temperature control is in the "O" position.
Beverage center may not be plugged in,
or plug may be loose.
House fuse is blown or circuit breaker
tripped.
Power outage.
Room or outside weather is hot.
Beverage center has recently been
disconnected for a period of time.
Doors are opened too frequently or too
long.
Beverage center door may be slightly
open.
Temperature control is set too low.
Beverage center gasket is dirty, worn,
cracked, or poorly fitted.
Interior beverage center Temperature control is set too low.
temperature is too cold.
Temperature control is set too warm.
Interior beverage center
temperature is too warm.
Door is kept open too long or is opened
too frequently.
Door may not be seating properly.
Beverage center has recently been
disconnected for a period of time.
The external walls can be as much as 30 °
F warmer than room temperature.
Use another circuit. If you are unsure about the
outlet, have it checked by a certified technician.
See SETTING THE TEMPERATURE CONTROL
section.
Ensure plug is tightly pushed into outlet.
Check/replace fuse with a 15 amp time-delay
fuse. Reset circuit breaker.
Check house lights. Call local electric company.
It's normal for the beverage center to work harder
under these conditions.
It takes 4 hours for the beverage center to cool
down completely.
Warm air entering the beverage center causes it
to run more. Open door less often.
See "DOOR PROBLEMS" section.
Adjust temperature control to a warmer setting.
Allow several hours for temperature to stabilize.
Clean or change gasket. Leaks in the gasket will
cause beverage center to run longer in order to
maintain desired temperature.
Adjust temperature control to a warmer setting.
Allow several hours for temperature to stabilize.
Adjust temperature control to a colder setting.
Allow several hours for the temperature to
stabilize.
Warm air enters the beverage center every time
the door is opened. Open the door less often.
See "DOOR PROBLEMS" section.
It takes 4 hours for the beverage center to cool
down completely.
This is normal while the compressor works to
transfer heat from inside the beverage center.
Beverage center external
surface temperature is
warm.
SOUND AND NOISE
Louder sound levels Modern beverage centers have increased This is normal. When the surrounding noise level
whenever beverage center storage capacity and more stable is low, you might hear the compressor running
is on. temperatures. They require a high while it cools the interior.
efficiency compressor.
Longer sound levels when Beverage center operates at high This is normal. Sound will level off or disappear as
pressures during the start of the "ON" the beverage center continues to run.
compressor comes on. cycle.
Exterior thermostat has activated the This is normal.
Fan runs when room
heater and fan.
temperature is below 45 ° F
Popping or cracking sound Metal parts undergo expansion and This is normal. Sound will level off or disappear as
contraction, as in hot water pipes, beverage center continues to run.
when compressor comes
On.
Refrigerant (used to cool beverage This is normal.
Bubbling or gurgling sound center) is circulating throughout the
like water boiling, system.