Installation Instructions PXDRIO Drain Kit
NOTE: Determine whetherdrain willbe located within the wall, on the indoor side, or will drain to the exterior of the building. Follow
appropriate instructions below depending on yourparticular type of installation.
Internal Drain (optional for new construction)
NOTE: Ifinstalling an internal drain, you MUST install a drain kit on
the wall sleeve before the wall sleeve is installed.
1,
Refer to Figure 3 below and locate the drain within the
"Primary" area for best drainage. Maintain at least a 1/2"
clearance from the embossed area.
2.
Using the mounting plate with the 1/2" hole as a template,
mark and drill two, 3/16" mounting holes and a 1/2" drain
hole.
,
Remove the backingfrom the gasket and mount it on the flat
side of the mounting plate. (See Figure 4.) Insert the drain
tube through the hole in the gasket and mounting plate so
the tube flange will be against the wall sleeve.
4. Position the assembly beneath the drilled holes and secure
it with #10-24 x 1/2" machine screws and lock nuts provided.
Seal the tops of the screws with silicone caulking.
5. Use 1/2" I.D.copper tube, PVC pipe, or vinyl hose (obtained
locally) to connect the internal drain tube to the drain system
in the building.
6. Referring to Detail A on page 6, locate and assemble the
(2) two cover plates and gaskets over the drain holes at the
rear of the wall sleeve.Attach them with the #10 sheet metal
screws provided. Makecertain that the four overflow slots at
the rear of the wall sleeve are not blocked (See drawing of
the back of the sleeve on page 6).
7. If a deep wall extension (PXWE) is used, after installing the
field supplied flashing, caulk as required. Be sure to caulk
around the flashing and the wall sleeve where the hole was
drilled for the drain tube.
Figure 3
DrainKitLocationandInstallation
Secondary area
Primary area _ no foam insulation --
If the drain must be located in the
secondary area, the foam insulation
must be cut away and removed to
allow access to the drain,
76 cm
Screw [_
Wail sleeve
Gasket t t
i
Mounting plateNut _ j _ I \\
)
5