DANGER is reserved for conditions and actions that are likely to cause serious or fatal injury.
WARNING is reserved for conditions and actions that can cause serious or fatal injury.
CAUTION is reserved for conditions and actions that can cause injury or instrument damage.
1. FEATURES AND MEASUREMENT FUNCTIONS
• 5999 count display
• Contoured body provides comfortable single handed grip
• Auto ranging
• Clamp illuminating LED and backlit LCD to facilitate working in dimly lit situations
• Auto shut off feature to extend battery life
• Auto shut off disable feature
• Low battery indicator
• Data hold
• Polarity indication: Automatic, + Implied, Negative Polarity Indicator
• Over-range indication: ‘0L’ or ‘-0L’
• Overload protection
• Non-contact voltage detection: 50 to 500 VAC
Temperature measurement: -20°C to 1000°C (-4°F to 1832°F) The K type thermocouple
provide (TP-01A) is rated 400°C max.
• Resistance measurement: 0.1Ω - 60MΩ
• Continuity check: Provides an audible indication above 50Ω
• Diode check: Measure the forward voltage drop across a diode junction
• Capacitance measurement: 1nF to 1mF
• DC voltage measurement: 600 VDC max.
• AC voltage measurement: 600 VAC max.
• AC current measurement: 600A max.
• Frequency measurement: up to 9.999MHz
• Duty cycle measurement
• Inrush current measurement: First 100ms from being triggered
• Relative measurement: Used for comparative measurement
• Peak Hold measurement: Captures the + Peak value, - Peak value and Peak to Peak value
2. SAFETY WARNINGS
This instruction manual contains warnings and safety rules which must be observed by
the user to ensure safe operation of the instrument and retain it in safe condition.
• Read through and understand the instructions contained in this manual before using the instrument.
• Keep the manual at hand to enable quick reference whenever necessary.
• The instrument is to be used only in its intended applications.
• Understand and follow all the safety instructions contained in the manual.
• It is essential that all safety instructions are adhered to.
• Failure to follow the safety instructions may cause injury, instrument damage
The symbol indicated on the instrument means that the user must refer to the related parts in the
manual for safe operation of the instrument. It is essential to read the instructions wherever the symbol
appears in the manual.
DANGER
• Never make measurement on a circuit in which voltage over 600V exists.
• Do not exceed the CAT rating of the measuring device
Do not attempt to make measurement in the presence of flammable gases.
The use of the instrument may cause sparking, which can lead to an explosion.
Transformer jaw tips are designed to not short the circuit during a test. If equipment under test has exposed
conductive parts extra precaution should be taken to minimize the possibility of shorting.
• Never use the instrument if its surface or your hand is wet.
• Do not exceed the maximum allowable input of any measuring range.
• Never open the battery cover during a measurement.
The instrument is to be used only in its intended applications or conditions.
Use in other than as intended may cause instrument damage or serious personal injury.