72
INSTALLATION INSTRUCTIONS
Water Saving Control
Water saving control is optional and is inactive
as default. To activate this control, appropriate
procedures must be followed.
Water saving control can reduce waste water at
initiation of hot water demand by reducing flow until
set temperature is reached of outlet hot water. It is
recommended to turn ON this control if the water
heater is installed in a drought area or anywhere
water conservation is needed.
Follow the steps below to turn ON the water
saving control.
1
Turn off the gas and water to the water heater by
closing the shut-off valves.
2
Remove the front cover panel on the water heater.
Control Board
Dip Switches
3
Find DIP Switch 1 located in the top-right portion at
the control board. The switch labeled “DIP 1” is the
top switch.
Change the third switch on “DIP 1” to the ON
position (UP).
Replace the front cover panel.
Turn on the gas and water to the water heater by
opening the shut off valves.
Follow the below steps to turn OFF the water
saving control.
Turn off the gas and water to the water heater by
closing the shut-off valves.
5
6
4
Start/Adjust
1
Loading ...
Loading ...
Loading ...