VC Series Manual 7
[1] A vent shall not terminate directly above a sidewalk or paved driveway that is
located between two single family dwellings and serves both dwellings.
[2] Permied only if veranda, porch, deck, or balcony is fully open on a minimum of
two sides beneath the oor.
For clearances not specied in ANSI Z223.1/NFPA 54, clearances are in
accordance with local installaon codes and the requirements of the gas supplier.
Clearance to opposite wall is 24 inches (60 cm).
For indoor models, you must install a vent terminaon to bring in combuson air and expel exhaust.
Direct Vent (Indoor Unit) Other than direct vent (Outdoor unit)
Ref
Descripon
Canadian Installaons
(CSA B149.1)
US Installaons
(ANSI Z223.1 / NFPA 54)
Canadian Installaons
(CSA B149.1)
US Installaons
(ANSI Z223.1 / NFPA 54)
A Clearance above grade, veranda, porch, deck, or balcony 12 inches (30 cm) 12 inches (30 cm) 12 inches (30 cm) 12 inches (30 cm)
B Clearance to window or door that may be opened 36 inches (91 cm) 12 inches (30 cm)
6 in (15 cm) for appliances ≤ 10,000 Btuh (3
kW), 12 in (30 cm) for appliances > 10,000
Btuh (3 kW) and 100,000 Btuh (30 kW), 36 in
(91 cm) for appliances >100,000 Btuh (30 kW)
4  (1.2 m) below or to
side of opening; 1  (300
mm) above opening
C Clearance to permanently closed window * * * *
D
Vercal clearance to venlated sot, located above the
terminal within a horizontal distance of 2 feet (61 cm)
from the center line of the terminal
* * * *
E Clearance to unvenlated sot * * * *
F Clearance to outside corner * * * *
G Clearance to inside corner * * * *
H
Clearance to each side of center line extended above
meter/regulator assembly
* * * *
I Clearance to service regulator vent outlet
Above a regulator
within 3  (91 cm)
horizontally of the
vercal center line of
the regulator vent
outlet to a maximum
vercal distance of 15
 (4.5 m)
*
Above a regulator within 3  (91 cm)
horizontally of the vercal center line of the
regulator vent outlet to a maximum vercal
distance of 15  (4.5 m)
*
J
Clearance to nonmechanical air supply inlet to building or
the combuson air inlet to any other appliance
36 inches (91 cm) 12 inches (30 cm)
6 in (15 cm) for appliances ≤ 10,000 Btuh (3
kW), 12 in (30 cm) for appliances > 10,000
Btuh (3 kW) and 100,000 Btuh (30 kW), 36 in
(91 cm) for appliances >100,000 Btuh (30 kW)
4  (1.2 m) below or to
side of opening; 1  (300
mm) above opening
K Clearance to a mechanical air supply inlet 6  (1.83 m)
3  (91 cm) above if
within 10  (3 m)
horizontally
6  (1.83 m)
3  (91 cm) above if within
10 feet (3 m) horizontally
L
Clearance above paved sidewalk or paved driveway
located on public property
7  (2.13 m) * 7  (2.13 m) [1] 7 . (2.13 m)
M Clearance under veranda, porch, deck, or balcony 12 inches (30 cm) * 12 inches (30 cm) [2] *
Terminal Clearances
AIR SUPPLY INLET
VENT TERMINAL
AREA WHERE TERMINAL IS
NOT PERMITTTED
X
V
SNOW
TERMINATION
Clearance in
Ref. A also
applies to
anticipated
snow line