Explosion Hazard
Use a new AGA or CSA approved gas supply
line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person
make sure gas pressure does not exceed 14"
water column.
Examples of a qualified person include:
licensed heating personnel;
authorized gas company personnel; and,
authorized service personnel.
Failure to follow these instructions can result
in death, explosion, or fire.
Observeall governingcodesand ordinances.
This installationmust conformwith all localcodesand
ordinances.In the absence of local codes, installation
must conform with American National Standard,
National Fuel Gas CodeANSI Z223.1 -- latest edition*.
Input ratings shown on the model/serial rating plate are
for elevations up to 2,000feet. For assistance when
installing the range at higher elevations, contact your
local Sears Service Center.
Type of gas: This range is design-certified bythe
American GasAssociation (A.G.A.)for usewith Natural
gas or, after proper conversion, for use with
L.P.gas. This range is factory set for use with Natural
gas. Gas conversion instructions are provided. The
model/serial rating plate located on the frame behind
the storage drawer has information on the types of gas
that can be used. If the types of gas listed do not
include the type of gas available, check with the local
gas supplier.
Peligro de Explosibn
Use una linea de suministro de gas nueva aprobada
por AGA o CSA.
Instale una v_lvula de cierre.
Apdete firmamente todas las conexiones de gas.
Si estb conectada a gas de P.L., haga que una
persona calificada asegure que la presibn de gas
no exceda de una columna de agua de 14".
Ejemplos de personas califlcadas son miembros
del personal de calefaccibn con licencia, personal
autorizado de la compa_ia de gas y personal de
servicio autorizado.
No seguir estas instrucciones puede ocasionar la
muerte, una explosibn o un incendio.
Observe todos los cbdigos y reglamentos vigentes.
Esta instalacion debe cumplir con todos los cbdigos y
reglamentos locales. A falta de c6digos locales, la
instalaci6n debe cumplir con American National
Standard, National Fuel Gas Code ANSI Z223.1--61tima
edici6n *.
Las clasificaciones de entrada que se indican en la
placa de modelo/serie son para elevaciones de hasta
2,000 pies sobre el nivel del mar. Para asistencia
cuando instale la cocina en lugares con mayor
altitud, contacte a su Centro de Servicio Sears.
Tipo de gas: El disefio de esta cocina ha sido
certificado por la American Gas Association (A.G.A.)
para uso con gas Natural o, despu_s de la debida
conversi6n, para uso con gas de P.L. Esta cocina ha
sido ajustada en la fbbrica para uso con gas Natural.
Las instrucciones de conversi6n de gas aparecen. La
placa de modelo/serie ubicada en el marco detr_s del
caj6n de almacenamiento, contiene informaci6n
sobre el tipo de gas que se puede usar. Si los tipos de
gas indicados no incluyen el tipo de gas disponible,
contacte a la compaflia de gas de su Iocalidad.
10
manual shutoff valve"open" position
valvula de cierra manual on la \
posicibn "abierta" _
to range __,r,_'_JJl_\ %.
gass.pp,,,__,,--,.27,,,,o
de gas
Conversionmustbe done by a qualified service
technician.
Gas supply line: Provide a gas supply line of 3/4" rigid
pipe to the range location. With L.P. gas, piping or
tubing size can be 1/2" minimum. A smaller size pipe
on longer runs may result in insufficient gas supply.
Usually, L.P.gas suppliers determine the size and
materials used in the system.
Pipe-joint compounds made for use with LP. gas must
be used on pipe threads only.
Flexible metal appliance connector: If local codes
permit, a new A.G.A. design-certified, 1/2" or 3/4" I.D.,
flexible metal appliance connector is recommended
for connecting range to the gas supply line. A 1/2"
male pipe thread nipple is needed for connection to
the female pipe threads of the inletto the appliance
pressure regulator. Do Not kink or damage the flexible
metal tubing when moving the range.
Rigid pipe connection: Requires a combination of pipe
fittings to obtain an in-line connection to the range. All
strains must be removed from the supply and fuel
lines so range will be level and in line.
Shutoff valve: The supply line must be equipped with
a manual shutoff valve. This valve should be located in
the same room asthe range and should be in a
location that allows ease of opening and closing. The
valve is for turning on or shutting off gas to the range.
Do Not block accessto shutoff valve.
Pressureregulator: The gas pressureregulator
supplied with this range must be used. The inlet
pressure to the regulator should be as follows for
proper operation:
NATURAL GAS:
Minimum pressure: 5 inchesWCP
Maximum pressure: 14 inchesWCP
LP. GAS:
Minimum pressure: 11 inches WCP
Maximum pressure: 14 inchesWCP
Contact local gassupplier if you are not sure about the
inletpressure.
La conversion debe ser hecha por un tecnico de
servicio calificado.
Linea de suministro de gas: Instale una linea de
suministro de gas de tubo rigido de 3/4" hasta la
cocina. Para el gas de P.L., el tubo debe medir un
mlnimo de 1/2". Un tubo m&s pequeflo para
recorridos m_s largos, podrla ocasionar un
suministro de gas insuficiente. Usualmente, las
compafiia proveedoras de gas de P.L. determinan
las dimensiones y los materiales usados en el
sistema.
Los compuestos para juntas de tubo disefiados
para uso con gas de P.L. deben usarse L_nicamente
en las roscas del tubo.
Conector de electrodomdsticos de metal flexible: Si
los c6digos locales Io permiten, se recomienda usar
un conector de electrodomesticos de metal flexible
con dibmetro interno de 1/2" 6 3/4", con disefio
certificado por la A.G.A., para conectar la cocina a
la linea de suministro de gas. Se necesita una
boquilla acopladora macho de 1/2" para la conexi6n
a la rosca de tuberia hembra del regulador de
presi6n. AI mover la cocina, no enrosque ni dafie el
tubo de metal flexible.
Conexion con tubo rigido: Requiere de una
combinaci6n de accesorios para tubos para Iograr
una conexi6n en la linea a la cocina. Deben
eliminarse las deformaciones de las lineas de
suministro y combustible para que la cocina estb
nivelada yen linea.
Valvula de cierre: La linea de suministro debe estar
equipada con una vblvula de cierre manual. Esta
v&lvula debe estar Iocalizada en la misma
habitaci6n en que estb la cocina, en un lugar que
facilite su apertura y cierre. El prop6sito de la
v&lvula es generar o interrumpir el suministro de
gas a la cocina. No bloquee el acceso a la valvula
de suministro.
Regulador de presibn: Se debe usar el regulador de
presi6n provisto con esta cocina. Para el debido
funcionamiento de la cocina, la presi6n de entrada
al regulador debe ser como sigue:
GAS NATURAL:
Presi6n minima: 5 pulgadas WCP
Presi6n mbxima: 14 pulgadas WCP
GAS de P.L:
Presi6n minima: 11 pulgadas WCP
Presi6n m_xima: 14 pulgadas WCP
Si no est& seguro sobre la presi6n de entrada,
consulte con la compafiia de gas de su Iocalidad.
11