Your pellet stove has been tested and listed for installation in residential, mobile home, and alcove applications in
accordance with the clearances given in FIGURES 3-5 and TABLE 1. Any reduction in clearance to combustibles may
only be done by means approved by a regulatory authority.
NOTE: Distance “C” on the left-hand side of your pellet stove may need to be greater than the minimum
required clearance for suitable access to the control panel.
SIDEWALL CLEARANCES
PARALLEL INSTALLATION
SIDEWALL CLEARANCES
CORNER INSTALLATION
ALCOVE CLEARANCES
PARALLEL A - Backwall to unit 3.00 / 76mm
B - Sidewall to ue 16.00 / 406mm
C - Sidewall to top edge of unit 12.00 / 305mm
CORNER D - Adjacent wall to unit 1.00 / 25.4mm
ALCOVE E - Alcove depth 36.00 - 914mm
F - Alcove height 60.00 - 1520mm
CLEARANCES