Thermostat Installation
On/Off High/Low Manual

A optional thermostat may help you maintain a constant house
temperature automatically. A millivolt thermostat is required. A
xed wall mount or hand held model can be used. The control
panel can be set up two ways to operate your stove in thermostat
mode.


Unplug stove from power outlet.
Remove control board from stove.
The two thermostat wires connect to the terminal block on the
lower left side of the back of the control board.
Insert the wires in the terminal side and tighten the two screws.

TO SWITCH BETWEEN ANY OF THE THREE MODES THE
STOVE MUST BE SHUT OFF, THE NEW MODE SELECTED,
AND THE STOVE RESTARTED.
MANUAL MODE
        

In this mode the stove will operate only from the control panel
as detailed in the ” section of this owner’s manu-
al.
HIGH/LOW THERMOSTAT MODE

When engaged in this mode the stove will automatically switch
between two settings. When warm enough, it will switch to the
#1 or low setting. The room air blower will also slow to its low-
est speed.
The Heat Level Advance setting on the bar graph will stay
where it was initially set. When the house cools below the ther-
mostat setting, the stove will switch to the feed rate of the heat
level advance setting.
ON/OFF THERMOSTAT MODE

In this mode when the home is warm enough the stove will shut
off. The fans will continue to run until the stove cools.
When the home cools below the thermostat setting, the stove
will automatically restart and run at the last feed rate setting.
 When in “high/low” or “on/off” thermostat mode –
Do not operate the stove higher than the #3 setting.
Set damper control rod approximately 1/4” to 1/2” out. This will
vary depending on elevation and weather conditions. Observe
stoves operation and adjust damper as necessary.