PANEL CONTROLS
The blowers and automatic fuel supply are controlled from a panel on the left side of
the appliance. The control panel functions are as follows:
ON/OFF SWITCH
When pushed the stove will automatically ignite. No other restarter is necessary.
The igniter will stay on for at least 10 and up to 15 minutes, depending on when
Proof of Fire is reached. The re should start in about 5 minutes.
The green light located above the On/Off button (in the On/Off box) will ash during
the ignition start-up period.
The Heat Level Advance is inoperable during the ignition start period. When the
green light continuously stays on the Heat Level Advance can be adjusted to
achieve the desired heat output.
 If the stove has been shut off, and you want to re-start it while it is still warm,
the “on/off” button must be held down for 2 seconds.
FUEL FEED SWITCH
When the “Fuel Feed” button is pushed and held down the stove will feed pellets
continuously into the burn pot.
While the stove’s auger system is feeding pellets the green light (in the “Fuel Feed”
box) will be on.
CAUTION: DO NOT USE THIS CONTROL DURING NORMAL OPERATION BECAUSE
IT COULD SMOTHER THE FIRE AND LEAD TO A DANGEROUS SITUATION.
Control Panel
HIGH FAN SWITCH
The room air fan speed varies directly with the feed rate. The “HIGH FAN” switch overrides this variable speed
function. It will set the room air blower speed to high at any feed rate setting.
When the “HIGH FAN” button is pushed the room air fan will switch to its highest setting.
When this button is pushed again the room air fan will return to its original setting based on the Heat Level Advance
setting.
RESET TRIM
Different size and quality pellet fuel may require adjustment of the “1” feed setting on the Heat Level Advance bar graph.
 The “RESET TRIM” button when adjusted
will allow for 3 different feed rate settings for the  To adjust simply push the “RESET TRIM” button
while the stove is operating at setting “1” and watch the bar graph.
When the “1” & “3” lights are illuminated on the bar graph the low feed rate is at its “lowest” setting. (Approx. 0.9
pounds per hour)
When the “1” light is illuminated on the bar graph the low feed rate is at its “normal” setting.
When the “1” & “4” lights are illuminated on the bar graph the low feed rate is at its “highest” setting.
When the stove is set on “1” the “reset trim” values will be shown on the Heat Level Advance bar graph. For
example if the Reset Trim is set to its lowest setting every time the stove is set to low the “1” and “3” lights will be
illuminated on the bar graph.
HEAT LEVEL ADVANCE
This button when pushed will set the pellet feed rate, hence the heat output of your stove. The levels of heat output
will incrementally change on the bar graph starting from level “1” to “4”.
NOTE: When dropping 3 or more heat level settings (4 to 1,) push the ‘High Fan’ button and allow the room air fan to
run at that setting for at least 5 minutes to prevent the stove from tripping the high temp thermodisc. If the high temp
thermodisc does trip see .