Schumacher PID-760 760 Watt Power Converter

OWNERS MANUAL - Page 5

For PID-760.

PDF File Manual, 39 pages, Read Online | Download pdf file

PID-760 photo
Loading ...
Loading ...
Loading ...
• 5 •
1.17 This device does not include an internal Ground Fault Circuit Interrupter (GFCI). For
GFCI protection, use a Coleman Cable 02822 GFCI outlet.
1.18 Restrictions on Use: This inverter may not be used in life support devices or systems.
Failure of this inverter can reasonably be expected to cause failure of that life support
device or system, or to affect the safety or effectiveness of that device or system.
2. PERSONAL SAFETY PRECAUTIONS
2.1 Wear complete eye and clothing protection when working near lead-acid batteries.
Always have someone nearby for help.
2.2 Remove all personal metal items from your body, such as rings, bracelets, necklaces
and watches. A lead-acid battery can produce a short circuit current high enough to
weld a ring to metal, causing a severe burn.
2.3 Never smoke or allow a spark or ame in the vicinity of the battery or engine.
3. BEFORE USING YOUR INVERTER
This inverter is designed to be used with a single battery, up to group 31 (130 Ah
or smaller). The recommended source of power is a 12 Volt deep-cycle battery,
due to their high reserve capacity. Automotive batteries are recommended for only
a short period of time of an hour or less.
Do not use the inverter with a product that draws a higher wattage than the
inverter can provide, as this may cause damage to the inverter and product.
When you turn on a device or a tool that runs on a motor, the device goes through
two stages:
1. Start Up – Requiring an initial surge of power (commonly known as the
“starting” or “peak” load).
2. Continuous Operation – Power consumption drops (commonly known as the
“continuous load”).
The wattage (WATTS) or amperes (AMPS) can normally be found stamped or
printed on most devices and equipment, or in the user’s manual. Otherwise,
contact the manufacturer to nd out whether the device you want to use is
compatible with a modied sine wave.
To calculate the wattage: Wattage = AMPS x 120 (AC Voltage).
To calculate the starting load: Starting Load = 2 x wattage.
In general, the startup load of the device or power tool determines whether your
inverter has the capability to power it.
Always run a test to establish whether the inverter will operate a particular piece of
equipment or device. In the event of a power overload, the inverter is designed to
automatically shut down.
Loading ...
Loading ...
Loading ...