12. Technical Data
This cooker is designed for use on Natural Gas, although a conversion for LP (LPG X Propane (2.54 kPa)) gas is packed with the
cooker.
INSTALLER: Please leave these instructions with the user.
DATA BADGE LOCATION: Cooker back, serial number repeater badge below oven door opening.
COUNTRY OF DESTINATION: Australia.
Connections
Gas (Rp ½ at rear right-hand side) Electric
Natural gas
1 kPa
230 V 50 Hz
Propane 2.75 kPa
See the appliance badge for test pressures.
Dimensions
Overall height minimum 905 mm maximum 930 mm
Overall width 900 mm
Overall depth 608 mm excluding handles; 670 mm including handles
Minimum space above the hotplate 650 mm
Refer to 'Positioning the Cooker'.
Ratings
Hotplate Bypass Screw
Natural Gas 1.0 kPa LP Gas 2.54 kPa
Injector Injector
Wok burner 55*
15.2 MJh-1
internal 88
15.0 MJh-1
internal 57
external 168 external 98
Large burner 41*
12.3 MJh-1 165 12.0 MJh-1 89
Medium burners 33*
6.2 MJh-1 115 6.2 MJh-1 67
Small burner 25*
3.7 MJh-1 92 3.3 MJh-1 45
Grill 77* 10 MJh-1 280 10 MJh-1 100
* The valve is tted with an adjustable bypass screw. The cooker is supplied with the bypass screw set for Natural gas. For LPG conversion the bypass screw
must be screwed all the way down.
Bypass Screw Natural Gas 1.0 kPa LP Gas 2.54 kPa
Natural
Gas
1.0 kPa
LP Gas
2.54 kPa
Injector Injector
Ovens 70 79
9.5 MJh-1 150 9.5 MJh-1 88
Maximum total electrical load at 230 V (approximate total including oven lights, oven fan, etc.): 2.6 kW.