LGJ CONTROL CONNECTION DIAGRAM
NUMBERED BOXES CORRESPOND WITH TERMINALS ON J1 CONNECTOR STRIP
If Neccessary, Remove The Connector Block From The Board To Secure Each Wire Connection
Connect field wires to any terminal number shown in the respective column. See control
options below for explanation of how field control will function for each terminal number.
OR
OR
OR
11
97
8435
OPEN
CLOSE
STOP
STANDARD
3 BUTTON CONTROL
10 5
SENSING
EDGE
8 5
9
11
ANY OPEN
CONTROL
(SEE NOTE)
65
ANY
OPEN & CLOSE
CONTROL
(SEE NOTE)
OR
OR
OR
11
97
8435
OPEN
CLOSE
STOP
OR
OR
OR
11
97
845
OPEN
CLOSE
STOP
OR
OR
OR
11
97
8435
OPEN
CLOSE
STOP
OR
OR
1145
OPEN
OFF
ON
CLOSE
2 BUTTON
CONTROL
(SEE NOTE)
3 BUTTON CONTROL
WITH
KEYED LOCK-OUT
3 BUTTON CONTROL
WITH
MULTIPLE CONTROL STATIONS
WHEN CONNECTING AN
OPEN CONTROL TO:
- Open control will require constant
pressure to keep door moving.
- Open control will only require
momentary contact and will set or
reset timer to close.
- Open control will only require
momentary contact and will NOT
set or reset timer to close.
WHEN CONNECTING AN
CLOSE CONTROL TO:
- Close control will require constant
pressure to keep door moving.
- Close control will only require
momentary contact.
DO NOT add unless using an
entrapment Protection device.
11
9
8
4
7
OPEN AND CLOSE CONTROL OPTIONS
IMPORTANT NOTE:
WHEN STOP BUTTON IS NOT USED, ADD A JUMPER FROM
TERMINAL 3 TO TERMINAL 5.
35
MAXIMUM RUN TIME: 1 - ON: Maximum run time is 90 seconds.
OFF: Maximum run time is 45 seconds.
MAXIMUM RUN TIME: 2 - ON: CLOSE limit switch B
OFF: CLOSE limit switch A
3 - OFF: (DO NOT ADJUST)
4 - OFF: (DO NOT ADJUST)
CONSULT FACTORY FOR ADJUSTEMENT
SWITCH #1 SETTINGS
SWITCH #2 SETTINGS
TIMER TO CLOSE SWITCH SETTING:
O = ON F = OFF
1 2 3 4
O O O O
F O O O
O F O O
F F O O
O O F O
F O F O
O F F O
F F F O
1 2 3 4
O O O F
F O O F
O F O F
F F O F
O O F F
F O F F
O F F F
F F F F
= Disabled
= 2 sec
= 3 sec
= 13 sec
= 15 sec
= 23 sec
= 32.5 sec
= 43.6 sec
= 72 sec
= 88 sec
= 107 sec
= 126sec
= 148 sec
= 172 sec
= 198 sec
= 224 sec
SETTING SETTINGTIME TIME
SWITCH ADJUSTMENTS