11
CONTROL WIRING
Standard C2 or B2 Wiring
Model MGJ operators are shipped from the factory with
jumper set for C2 wiring, which requires constant pressure
on button to close the door. If momentary contact in close
direction is desired (B2 wiring) you must include an
entrapment protection device. See close control jumper
setting below.
Constant pressure on close (C2 wiring)
Red jumper wire was placed on terminal #2 in the
electrical enclosure. The operator will require constant
pressure on close control in order to keep door moving
in the close direction.
Momentary contact on close (B2 wiring)
Move red jumper wire from terminal #2 to terminal #3.
The operator will require only momentary contact to
close the door.
LOCATING THE CONTROL STATION
All operators are supplied with some type of control station. Generally a three button station (OPEN/CLOSE/STOP) is
provided. A two-position key switch or control station (OPEN/CLOSE) may be added or substituted when requested at the
time of order. Mount the control station near the door.
WARNING
W A R N I N G
OPEN
OPEN
CLOSE
CLOSE
STOP
Control Station
WARNING Notice
Push
Buttons
TO PREVENT ENTRAPMENT DO
NOT START DOOR DOWNWARD
UNLESS DOORWAY IS CLEAR
IMPORTANT: Mount WARNING NOTICE beside or
below the push button station.
MOUNT WARNING NOTICE
DETERMINE WIRING TYPE
Refer to the wiring diagram located on the inside cover the electrical box to determine the type of control wiring.
SPECIAL CONTROL WIRING
If your operator was shipped from the factory with non-
standard control wiring or with optional accessories that
require additional instructions, refer to the wiring
diagram(s) indicated in the special control wiring data box.
When a replacement wiring diagram is present, wiring
diagrams in this manual will not apply. Refer only to the
replacement wiring diagram for all connections.
IMPORTANT NOTE: If your wiring diagram is
missing, or you are unsure of the wiring type for
your operator, contact the customer service
department @ 1-800-528-2806.
MODEL MGJ
Standard G2 Wiring
Model LGJ operators are supplied with type G2 control
wiring. Study the control features list below to determine
the features and type of control equipment that may be
used with your operator.
Entry Controls:
OPEN control requiring maintained contact.
OPEN control requiring only momentary contact.
CLOSE control requiring maintained contact.
CLOSE control requiring only momentary contact.
OPEN/CLOSE single control requiring momentary contact.
STOP control requiring momentary contact.
Safety Devices:
External Interlock switch to disable all control pneumatic
safety (N.C.) to STOP while closing Safety Device to
REVERSE while closing Door Lock Sensing Circuit.
Operational Features:
REVERSE (if closing) with momentary contact on OPEN.
AUTOMATIC TIMER to CLOSE from any device.
AUTOMATIC TIMER to CLOSE from selected devices.
DELAY REVERSE in either direction for 1 second.
STOP after maximum run time is exceeded.
Note: Refer to LGJ control connection diagrams on
page 15.
MODEL LGJ
To prevent possible SERIOUS INJURY or DEATH, install
reversing sensors when the 3-button control station is out of
sight of the door or ANY other control (automatic or manual)
is used. Reversing devices are recommended for
ALL installations.
WARNING
CAUTION
WARNING
WARNING