17
9.2 Indoor Unit
9.2.1 How to Fix Installation Plate
The mounting wall shall be strong and solid enough to prevent it from the vibration.
The center of installation plate should be at more than at right and left of the wall.
The distance from installation plate edge to ceiling should more than .
From installation plate center to unit’s left side is .
From installation plate center to unit’s right side is .
B : For left side piping, piping connection for liquid should be about from this line.
: For left side piping, piping connection for gas should be about from this line.
1 Mount the installation plate on the wall with 5 screws or more (at least 5 screws).
(If mounting the unit on the concrete wall, consider using anchor bolts.)
o Always mount the installation plate horizontally by aligning the marking-off line with the thread and using
a level gauge.
2 Drill the piping plate hole with ø2 3/4" (ø70 mm) hole-core drill.
o Line according to the left and right side of the installation plate. The meeting point of the extended line is
the center of the hole. Another method is by putting measuring tape at position as shown in the diagram
above. The hole center is obtained by measuring the distance namely 5 1/16" (128 mm) for left and right
hole respectively.
o Drill the piping hole at either the right or the left and the hole should be slightly slanting to the outdoor
side.
9.2.2 To Drill a Hole in the Wall and
Install a Sleeve of Piping
1 Insert the piping sleeve to the hole.
2 Fix the bushing to the sleeve.
3 Cut the sleeve until it extrudes about 19/32"
(15 mm) from the wall.
4 Finish by sealing the sleeve with putty or
caulking compound at the final stage.
Model
Dimension
123 456
ME7***
or
19
9
/
32
"
(490 mm)
3
7
/
32
"
(82 mm)
17
9
/
32
"
(439 mm)
17"
(432 mm)
1
11
/
16
"
(43 mm)
3
3
/
4
"
(95 mm)
W
all
Wall
Wall
Installation plate
1
2
screw
More than 1
More than 1
Measuring
Tape
9
17
/
32
"
(241.5 mm )
PIPE HOLE CENTER
PIPE HOLE
CENTER
DISTANCE TO
PIPE HOLE
CENTER 128 mm
5
1
/
16
"
(128 mm)
5
1
/
16
"
(128 mm)
9
17
/
32
"
(241.5 mm )
5
1
/
16
"
(128 mm)
More
tha n 2
For best strength of
INDOOR unit installation,
it is highly recomm ended
to loca te
”at5position
as shown.
DISTANCE
TO PIPE
HOLE
CENTER
128 mm
CAUTION
When the wall is hollow, please be sure
to use the sleeve for tube assembly to
prevent dangers caused by mice biting
the connection cable.
19
/
32
" (15 mm)
Putty or caulking compound
ø2
3
/
4
"(ø70mm)
through hole
Indoor
Outdoor
Sleeve for
tube
assembly
Approx.
7
/32" -
9
/32"
(5-7 mm)
Bushing for tube
assembly
Wall
Loading ...