Loading ...
Loading ...
Loading ...
30_ installation instructions
Flexible connector hookup
Installer: Inform the consumer of the location of the gas shut-o valve.
If your area requires a rigid pipe
hookup, contact a qualified
installer, service agency, or gas
supplier.
The gas shut-o valve should
be installed in an accessible
location in the gas piping,
external to the appliance, for the
purpose of turning on or shutting
o the gas to the appliance.
Step 3. Convert to lp gas (optional)
All new gas ranges are shipped from the factory set up to use natural gas. Any
Samsung gas range can be converted to use LP gas. Refer to page 78 in the
User Manual to contact a qualified service technician.
The conversion process should only be performed by a qualified LP gas installer.
Conversion instructions and LP orifices will be supplied with the LP conversion
kit. The conversion to LP requires all burner orifices to be changed (5 surface
burners and 2 oven burners).
In addition, the nozzle on the gas pressure regulator needs to be reversed. All
replaced orifices must be left with the consumer, including the instructions and
retrofit sizes and orifice indication.
BURNER ORIFICE SIZES AND
OUTPUT RATINGS
(LP Gas [Propane] 10 in WCP)
BURNER ORIFICE SIZES AND
OUTPUT RATINGS
(Natural Gas 5 in WCP)
Burner
Location
BTU Rate
Orifice Size
[mm]
Burner
location
BTU Rate
Orifice size
[mm]
RF¹ 14500 1.12 RF¹ 18000 1.92
RF² 12500 1.06 RF² 17000 1.92
LF¹ 11500 1.04 LF 15000 1.78
LF² 10000 0.98 RR 5000 1.01
RR 4000 0.62 LR 9500 1.40
LR 7500 0.83 CTR 9500 1.38
CTR 7500 0.83 BAKE 18000 1.90
BAKE 15000 1.15 BROIL 13500 1.64
BROIL 11500 1.02
¹ Model NX58H5650W* ² Model NX58H5600S*, NX58J5600S*
Pressure
Regulator
Adapter
Flex Connector
(6-ft max.)
Adapter
Gas Shut-O Valve
0.5-in or 0.75-in Gas Pipe
Tubing Line to
Oven Burner
Control Valve
Tubing Line
to Cooktop
Control
Manifold
Gas Flow into Range
Loading ...