From Inside the Dryer Cabinet:
Lint should be removed every 2 years or more often, depending
on dryer usage. Cleaning should be done by a qualified person,
From the Exhaust Vent:
Lint should be removed every 2 years, or more often, depending
on dryer usage.
Vacation care
Operate your dryer only when you are at home. If you will be on
vacation or not using your dryer for an extended period of time,
you should:
1. Unplug dryer or disconnect power.
2. Clean lint screen. See "Cleaning the Lint Screen."
1 1
Moving care
For power supply cord-connected dryers:
1. Unplug the power supply cord.
2. Make sure leveling legs are secure in dryer base.
3. Use masking tape to secure dryer door.
E_ectricaI Shock Hazard
Disconnect power before servicing.
Replace aimparts and panels before operating.
Failure to do so can reeutt in death or electrical shock.
For direct-wired dryers:
1. Disconnect wiring.
2. Make sure leveling legs are secure in dryer base.
3. Use masking tape to secure dryer door.
The dryer light automatically turns on inside the dryer drum when
you open the door.
To change the drum light
1. Unplug dryer or disconnect power.
2. Open the dryer door. Locate the light bulb cover on the back
wall of the dryer. Remove the screw located in the lower right
corner of the cover. Remove the cover.
3. Turn bulb counterclockwise. Replace the bulb only with a
10-watt appliance bulb, Replace the cover and secure with
the screw.
4. Plug in dryer or reconnect power.
TROUBLESHOOTING
First try the solutions suggested here and possibly avoid the cost of a service call.
Dryer displaying code message Clothes are not drying satisfactorily
"PF" (power failure), check the following:
Is the dryer connected to the power supply?
Checkthe following:
Is the lint screen clogged with lint?
Was the dryer connected to a power supply during
installation or a power failure?
Press STOP to clear display.
Was the drying cycle interrupted by a power failure?
Press START to restart the dryer.
"E" Variable (El, E2, E3) service codes:
Call for service,
Is the exhaust vent or outside exhaust hood clogged with lint,
restricting air movement? Run the dryer for 5-10 minutes.
Hold your hand under the outside exhaust hood to check air
movement. If you do not feel air movement, clean exhaust
system of lint or replace exhaust vent with heavy metal or
flexible metal vent. See "Installation Instructions."
Is the exhaust vent crushed or kinked? Replace with a heavy
metal vent or flexible metal vent. See "Installation
Instructions."