Loading ...
Loading ...
Loading ...
INSTALLATION & USE
OPERATION OF CONTROLS
mid
low
light
on/off
The hood is operated using the touch control.
The on/off switch turns the hood on and off.
The light switch turns the lamps on and off.
The blower switch turns the blower on to three speed settings:
1 - LOW SPEED
2 - MEDIUM SPEED
3 - BOOSTER
Grease Filters
The grease filters should be cleaned frequently. Use a warm detergent
solution. Grease filters are washable.
See “INSTALL FILTERS” section for removal and installation instructions.
INSTALL THE DUCTWORK
(DUCTED HOODS ONLY)
Caution: To reduce the risk of fire, use metal
ductwork is preferred.
1. Decide where the ductwork will run
between the hood and the outside.
2. A straight, short duct run will allow the
hood to perform most efficiently.
3. Long duct runs, elbows, and transitions
will reduce the performance of the hood. Use as few of them as
possible. Larger ducting may be required for best performance with
longer duct runs.
4. The air must not be discharge into a flue that is used for exhausting
fumes from appliances burning gas or other fuels" "Regulations
concerning the discharge of air have to be fulfilled.
5. Install wall cap. Connect round metal ductwork to cap and work back
towards hood location. Use duct tape to seal the joints between
booster