iNSTALLiNG THE WATER LiNE (ONSOMEMODELS)
BEFORE YOU BEGIN
I),e{ommended copper water supply kits are WX8X2,
WX8X3 or WX8X4, depending on the amount of
tubing you need. Approved plastic water supply lines
are GE SmartConnect'" Refl'igerator Tubing
(WX08X10002, WX08X10006, WX08X10015 and
WX08X10025).
When omnecting your refl'igerator to a GE Reverse
Osmosis _,Liter System, the only approved installation
is with a GE RVKit. For other reverse osmosis water
systems, fl)llow the manufimturer's recommendations.
This water line installation is not warranted by the
refl'igerator or icemaker manufiicturer. Follow these
instructions carefully to minimize the risk of expensive
water damage.
_%_ter hammer (water banging in the pipes) in house
plmnbing can cause damage to refl'igerator parts and
lead to water leakage or flooding. Call a qualified
plumber to correct water hammer beflwe installing the
water supply line to the refl'igerator.
To prevent burns and product damage, do not hook
up the water line to the hot water line.
If you use your refi'igerator befl_re connecting the
water line, make sure the icemaker power switch is in
the 0 (off) position (on power switch models) or the
feeler arm is in the STOP (up) position (on _beler arm
models).
Do not install the icemaker tubing in areas where
temperatm'es _hll below fl'eezing.
When using any electrical device (such as a power
drill) during installation, be sm'e the device is double
insulated or grounded in a manner to prevent the
hazard of electric shock, or is battery powered.
All installations must be in accordance with local
plmnbing code requirements.
WHAT YOU WiLL NEED
/
Copper or GE SmaactCmmect'" Refrigerator Tubing
kit, 1/4" outer diameter to connect the refl'igerator
to the water sui_ply. If using copper, be sure both ends
of the robing are cut square.
To deternfine how much robing you need: Measure
the distance fl'Oln the water wflve on the back of the
refl'igerator to the water supply pipe. Then add 8'
(2.4 m). Be sure there is sufliciei_t extra robing (about
8' [2.4 in] coiled into 3 turns of about 10" [25 cin]
dialneter) to allow the reli'igerator to move otlt frolll
the wall atter installation.
GE Smart(_olmect '' Refl'igerator Tubing Kits are
awfilable in the following lengths:
2' (.6 m) - _SX08X10002
6' (1.8 m) - X_3X08X10006
15' (4.6 m) - X_SX08X10015
25' (7.6 m) - WX08X10025
Be sure that the kit wm select allows at least 8' (2.4 m)
as described above.
NOTE: The only GE approved plastic tubing is that
supplied in GE SmartConnect '_'Refrigerator Tubing
kits. Do not use any other plastic water supply line
because the line is raider pressure at all times. Certain
types of plastic will crack or rupture with age and cause
water damage to your home.