GE - General Electric GE20L08BAR GE 18 Gallon Side Port Lowboy Electric Water Heater

User Manual - Page 9

For GE20L08BAR.

PDF File Manual, 66 pages, Download pdf file

Loading ...
Loading ...
Loading ...
49-6000247 Rev. 1 9
Tools needed:
• Socket/Torque Wrench
• 1 1/16” Socket
• Pipe Joint Compound or Pipe Thread Sealant Tape
Anode Rod, if needed
* See page 18 for part ordering instructions
To Service Anode Rod:
1. Disconnect power, shut off the water supply, drain
the water lines of the home. Drain the water heater
through the lower drain valve.
2. Using a 1 1/16” socket, unscrew the anode rod, then
lift out to inspect.
3. Inspect and replace if necessary.
4. To install the anode rod, seal the threads with pipe
joint compound or pipe thread sealant tape, thread
into the port tighten.
5. Turn water supply on, open a tap to remove any air in
plumbing system, fill water heater with water, inspect
for leaks, then turn the power on.
NOTE: Do not turn on power until water heater is
completely filled.
Anode Rod Maintenance and Service
CAUTION - IMPORTANT SAFETY NOTICE
This information is intended for use by individuals
possessing adequate background of electrical,
electronic and mechanical experience. Any attempt
to repair a major appliance may result in personal
injury and property damage. The manufacturer or
seller cannot be responsible for the interpretation
of this information, nor can it assume any liability in
connection with its use.
CARE AND CLEANING
Replace Anode
Rod if more than
6” of core wire is
exposed.