Alevelfloorwithamaximumslopeof1in.(2.5cm)under
entiredryer.Ifslopeisgreaterthan1in.(2.5cm),install
ExtendedDryerFeetKit,PartNo.279810.Clothesmaynot
tumbleproperlyandautomaticsensorcyclesmaynot
operatecorrectlyifdryerisnotlevel.
For a garage installation, you will need to place the dryer at
least 18 in. (46 cm) above the floor. If using a pedestal, you
will need an additional 6 in. (15.24 cm).
Do not operate your dryer at temperatures below 45°F (7°C). At
lower temperatures, the dryer might not shut off at the end of an
automatic cycle. This can result in longer drying times.
The dryer must not be installed or stored in an area where it will be
exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector.
Installation clearances
The location must be large enough to fully open the dryer
door.
Dryer Dimensions
Additional spacing should be considered for ease of
installation and servicing.
Additional clearances might be required for wall, door and
floor moldings.
Additional spacing of 1 in. (2.5 cm) on all sides of the dryer is
recommended to reduce noise transfer.
Companion appliance spacing should also be considered.
=
(138.81 _m)
38 I,
(96.52 cm)
L
L
]
* Most installations require a minimum 51/2in. (14 cm) clearance
behind the dryer for the exhaust vent with elbow. See "Venting
Requirements."
+
Minimum installation spacing for custom undercounter
installation
The dimensions shown are for the minimum spacing allowed.
Custom undercounter installation - Dryer only
Minimum installation spacing for recessed or closet
installation, with or without a pedestal
The dimensions shown are for the minimum spacing allowed.
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
Closet installation - Dryer only
_['-- 48 in. 2
(310cm2) -
24 in.2
(155cm2)
10"l<- 8_.+/'"t 6"1
(Ocm) (BOom) (Ocm)
3"
7,6 cm)
f
(7,63;m)
I 2
1. Side view- closet or confined area
2. Closet door with vents
Recessed or closet installation - Dryer on pedestal
O" ---+P._F i 27" _-- 0"
(Ocm) i (68,6 cm) --(O cm)
H
H /_ !8" mln.
lo' I<-38_/_'+'l 6"
(Ocm) (80 cm) (Ocm)
1 2
!. Recessed area
2. Side view - closet or confined area
0" 27" 0"
(0 ore) "_(68.6 crr_'_-_l "_-- (0 era}
Loading ...