Troubleshooting - What to check when problems occur
Problem PossibleCause Remedy
Nothingworks. Cooktopis notconnectedto
electricalpower.
Powersupplyis notenergized.
Havecooktopconnectedto a properlysized
electricalpowersupplybya qualifiedtechnician.
Haveanelectriciancheckpowersupply,including
thehousecircuitbreaker,wiringandfuses.
Ignitorsdo notspark.
Circuitbreakeristripped.
Housefuseis blown.
Poweroutageinlocalarea.
Resetcircuitbreaker.
Replacehousefuse.
Contactpowercompany.
Sparking,butnoflameignition.
Gasshut-offvalveison "off'
position.
Gassupplyis interrupted.
Turnshut-offvalveto "on"position.
Contactgas company.
Bumersignitebutflame is extremely Burnerringportsare clogged. Cleanbumerringportswithstraightenedpaper
large,distortedoryellow. Burnerportsor burnercapsarenot clip,needleor wire.
poeitioeedproperly. Removeandcarefullyre-installbumerringsand
caps.
Cooktopis beingoperatedonthe Ensurethatthe typeof cooktopmatchesthegas
wrongtypeof gas. supply(naturalgasor L.P.gas).
Regulatoris not installed,isfaulty, Checkinstallation,replaceregulator,or set
oris setforthe wrongtype of gas. regulatorfor correctgastype.
Bumerflamegoesoutat lowsetting. Lowgassupplypressure. Contactgascompany.
Airintakeholesaroundknobsare Removeobstructioe.
obstructed.
Igniterssparkcontinuouslyafter
flameignition.
Powersupplyis notgrounded. Havepowersupplyproperlygrounded.
Powersupplypolarityis reversed. Havepolaritycorrected.
Ignitersarewetor dirty. Cleanor dryigniters.