Performance Data Sheet
GE SmartWater Filtration System
GWF Cartridge
Health Claim Performance Certified by NSF/ANSI*
qOO% safety factors built in for unmetered usage)
Standard No. 42: Aesthetic Effects
Paxmneter
Chhwine
T & ()
Particldate**
Paxaaneter
USEPA
MCL
USEPA
Tud)idity
Cysts
I_ead at PH 6.5
I_ead at pH 8.5
I,indane
Atrazine
2,4-D
Asbestos
]Jafluent
Challenge
1.9 ppm
200,000
Effluent
Average
0.02 ppm
3,978
Standard No. 53: Health Effects
]Jafluent Effluent
Ma_rnurn
/)./)5 ppm
7,800
% Reduction
Average _urn
98.90% 97.37%
98.00% 96.10%
%Reduction
MCL
1 NTU***
99.95% Reduction
15 ppb
15 ppb
0.0002 ppm
0.003 i)pm
0.100 ppm
99%
Challenge
24.3 NTU
105,750
160 17171)
150 17171)
0.00062 ppm
0.0084 pi7m
0.272 i7pm
690 MFI,/ml
Average
0.07 NTU
26
1 17171)
1.8 ppb
0.00005 ppm
0.002 ppm
0.042 ppm
0.32 MH,/mI
Maximmn
0.1 NTU
D D
1 ppb
4.3 ppb
0.00005 ppm
0.003 ppm
0.090 ppm
1.2 MFL/ml
* Tested using a flow rate of 0,5gpm (1,8927I/m); pressure of 120psig (8,437kg/cm 2);pH of Z5+_0,5;temp, of 68%4,5° F (20°+_2,5° C)
** Measurement in particles/ml
**_ NTU = Nephelometric Units
Average
99.71%
99.97%
99.37%
98.8o%
91.93%
76.19%
84.89%
99.95%
_Dnl
99.59%
99.95%
99.37%
97.13%
91.93%
64.28%
67.63%
99.82%
Operating Specifications
y
Capa('it}: certified for up to 300 galhms (l 135 1); up to one year
i_i;:Pressm'e requirement: 40-121) psi (2.8-8.2 bar), non-shock
"0 3 ''°
Temperature: 33 °-11)0 ° F ( .o -. _ C)
N Fh)w rate" 0 ,5 _,om ( 1.9 lpm)
General Installation/Operation/Maintenance Requirements
Hush new cartridge at hill flow for .3 minutes to Imrge, out trapped air.
N Replace cartridge when flow becomes too sh)w.
Special Notices
i_i;:Installation instructions; parts and service axailabilit}; and standard xsarrant} are included with the i)roduct xdmn shii)i)ed.
INThis drinking water sxstem must be maintained according to manufacturer's instructions, including replacement of
filter cartridges.
N Do not use with water that is microbioh)gicall} unsafe ()r ()f unkn()wn tlualit } without adequate disinfection befl)re or
after the system. S_stems certified fl)r cyst reduction max be used on disinfected water that mm contain filterable c_sts.
N The contaminants or other substances remoxed or reduced b} this _sater treatment s}stem are not necessaril} in }our _sate_:
>_Check for compliance with the state and local laws and regulations.
Syslem Tesled and Certified by NSF Int( rnational againsl ANSI/NSF
Standard 42 & 53 tot the reduction off
Standard No. 42: Aesthetic Effects
Chemi( al [nit
"['_lste and ()dot Reduction
Chh)rine Reduction, Class I
Mechanical Fihration [ nit
Particulate Re(luction, Class I
Standard No. 53: Health Effects
Chemical Reduction [nit
Lead and Atrazine Reduction
Lindane an(12,41) Reduction
Mechanical Fihration Unit
Turbi(litv Reduction
Cyst and Asbestos Reduction
Manufi_ctm'ed fi)r: General Electric (_ompanv I,ouisx411e KY 4/)225