User Manual Phoenix 4024848 Guardian Air Scrubber

Documents for Phoenix 4024848

The following documents are available:
User Manual Other Documents Photos
4024848 photo
Lit. No. TS-265-0602
PHOENIX GUARDIAN
H. E. P. A. SYSTEM
Therma-Stor Products
Box 8050 Madison, WI 53708
Toll Free 1-800-533-7533
Local 1-608-222-5301
PHOENIX GUARDIAN Operation & Service Instructions
Table of Contents
1. Specifications .........................................................1
2. Operation.................................................................1
2.1 Transporting the Phoenix Guardian...........1
2.2 Location......................................................1
2.3 Electrical Requirements.............................2
2.4 Limiting Amp Draw.....................................2
2.5 Air Ducting..................................................2
2.5a Inlet Ducting...............................................2
2.5b Outlet Ducting ............................................3
2.6 Negative Air Ducting ..................................4
2.7 Power/Speed Switch..................................5
2.8 Hour Meter.................................................5
3. Maintenance............................................................5
3.1 Air Filters....................................................5
3.1a Carbon/Potassium Permanganate Filter....5
3.2 Checking Airflow ........................................6
4. Service.....................................................................6
4.1 Warranty.....................................................6
4.2 Blower Motor Replacement........................6
5. Wiring Diagram.......................................................7
6. Service Parts List....................................................8
Serial No. ________________________________
Purchase Date ____________________________
Dealer's Name ____________________________
Read the operation and maintenance instructions
carefully before using this unit. Proper adherence to
these instructions is essential to obtain maximum benefit
from your Phoenix Guardian dehumidifier.
1 Specifications
Model: Phoenix Guardian
Electrical: 110-120 Vac, 12 Amps, grounded
Airflow: Hi speed: 1400 CFM w/o external ducting
Lo speed: 900 CFM w/o external ducting
Duct Connections:
Inlet: 18” diameter: 18” flex duct can be connected
directly to the top; 12” dia. adapter for flex duct
Outlet: 10.5” square: (3) Rectangular wire-form collars
for lay-flat plastic ducting; (1) for 14” & (2) for
10”; 12” diameter adapter for flex duct
Size: 25” wide (26.5” over axle)
28" deep w/ handle
39" tall
Weight: 121 lbs.
2 Operation
2.1 Transporting the Phoenix
The Phoenix Guardian should be upright when
transported by vehicle. It may be tipped on to its back for
loading and moving by hand.
2.2 Location
Note the following precautions when locating the Phoenix
Guardian:
It is designed to be used INDOORS ONLY.
If used in a wet area, plug it into a GROUND FAULT
INTERRUPTER.
DO NOT use the Phoenix Guardian as a bench or
table.
It must always be used in the upright position.
The air inlet on top & the front outlet should be at
least 1 foot from walls and other obstructions to
airflow.
www.sylvane.com 1-800-934-9194
Loading ...
Loading ...
Loading ...