Installationof the range==:.
Read these instructions completely and carefully.
[] 3-Wire Power Cord Installation
_kWARNING:Theneutralor ground wire of thepower cord
must be connected to the neutral terminal located in the center of the
connector block. The power leads must be connected to the outside
(brass colored) terminals.
Remove the _ wire terminal screws fl'om tile connector block. Insert screws
through each power cord terminal ring _tnd into the connector block until the
screws eng_tge the nuts. Be cert_fin that the center wire is connected to the center
s(rew of the connector block. Tighten screws securel).
Do NOTremove ground strap connection.
Connectorblock
Neutralterminal
Ground strap
J
Power cord