4. Hanging Bracket Installation.
page 3
ON
OFF
ON
OFF
3. Installation Preparation.
hanging bracket
10 feet
(3.05m) (76cm)
30
inches
blade edge
Turn off circuit breakers to current fixture from breaker
panel and be sure operating light switch is turned to the
OFF position.
WARNING: Failure to disconnect power supply prior to
installation may result in serious injury.
Remove existing fixture.
WARNING: When using an existing outlet box, be sure the
outlet box is securely attached to the building structure and
can support the full weight of the fan. Ensure outlet box is
clearly marked "Suitable for Fan Support." If not, it must be
replaced with an approved outlet box. Failure to do so can
result in serious injury.
CAUTION: Be sure outlet box is grounded properly and that
a ground wire (GREEN or bare) is present.
Remove canopy cover from underside of canopy by
turning canopy cover counterclockwise. Remove
hanging bracket from canopy.
Install hanging bracket to outlet box using original
screws, spring washers and flat washers provided with
new or original outlet box.* Arrange electrical wiring
around the back of the hanging bracket and away from
the hanging bracket opening.
*NOTE: It is very important that you use the proper
hardware when installing the hanging bracket as this will
support the fan.
To prevent personal injury and damage, ensure that
the hanging location of the fan allows the fan cage a
clearance of 10 feet (3.05m) from the floor and that
the edges of the fan cage will be at least 30in. (76 cm)
from any wall or obstruction.
This fan is suitable for room sizes up to 400 square feet
(37.2 square meters).
Installation requires these tools:
Phillips screwdriver, flathead screwdriver, adjustable
pliers or wrench, stepladder, wire cutters, and rated
electrical tape.
spring washers
outlet box screws
flat washers
This fan can be mounted with a downrod on a regular
(no-slope) ceiling ONLY. Fan CANNOT mount as a
flushmount installation NOR on a vaulted ceiling.
12ft. - 20ft.
12ft. - 20ft.
(3.66m - 6.1m)
(3.66m - 6.1m)
downrod
installation
CANNOT be
installed on
angled or
vaulted ceilings
flushmount
installation
canopy
cover
canopy