INSTALLATION
IMPROPER INSTALLATION
The use of other components other than stated
herein could cause bodily harm, heater damage, and
void your warranty. The manufacturer will not be held
responsible for damage caused by the malfunction
of a stove due to improper venting or installation.
FLOOR PROTECTION
This heater must have a non-combustible oor
protector (UL1618 ember protection) installed
beneath it if the oor is of combustible material.
US - Floor protector should be UL listed or equal too,
needs to extend 6” to the front, 6” to each side, 1” to
the rear of the unit. Under and 2” beyond each side
of the cleanout tee if an interior vertical installation.
Canada - Floor protector should comply with CAN/
ULC standards. Needs to extend 18” to the front, 8”
beyond each side of the unit.
A Back to Stove
U.S.A 1” 26 mm
CAN 8” 204 mm
B Side to Stove
U.S.A 6” 153 mm
CAN 8” 204 mm
C Front to Stove
U.S.A 6” 153 mm
CAN 8” 204 mm
D Back to Flue 2” 51 mm
CLEARANCES
Your pellet stove has been tested and listed for
installation in residential, mobile home in accordance
with the clearances given below. For safety reasons,
please adhere to the installation clearances
and restrictions. Any reduction in clearance to
combustibles may only be done by means approved
by a regulatory authority.
E Side Wall to Stove 10” 245 mm
F Side Wall to Vent Pipe 11-1/2” 292 mm
G Back Wall to Stove 11-7/8” 302 mm
H Back Wall to Vent Pipe 3” 76 mm
J Ceiling to Floor 84” 2134 mm
K Ceiling to Stove 53-7/8’ 1434 mm
L Side Wall to Stove 7-1/2” 191 mm
M Side Wall to Vent Pipe 11-1/4” 286 mm
N Back Wall to Vent Pipe 7-1/2” 191 mm