7. Turn the gas supply on by moving the shuto valve to the open position. The
valve is open when the handle is parallel to the gas pipe.
8. Check all connections for leaks by applying a noncorrosive leak-detection
solution. Bubbles will identify leaks. If leaks are found, close the shuto valve,
retighten the joint, open the shuto valve, and check again.

STEP 3 - CONNECT TO AN EXHAUST SYSTEM

1. Make sure that the exhaust system is free and clear of old lint accumulation prior
to connecting the dryer.
2. Use 4" (102 mm) rigid or exible metal ducting to connect the dryer exhaust
outlet to the exhaust system.
3. Use clamps to seal and secure all joints. Exhaust ducting must not be connected
with screws or other fastening devices which extend into the interior of the duct.
NOTES:
Do not use plastic or metal foil exible ducting. Excessive lint can build up inside
the ductwork, restrict air ow, and create a re hazard. Restricted air ow will
increase drying time.
The dryer shall not be exhausted into a chimney, a wall, a ceiling, an attic, a crawl
space, or a concealed space of a building.
The dryer must be exhausted to the outdoors. If the dryer is not exhausted
outdoors, some ne lint will be expelled into the laundry area. An accumulation
of lint in any area of the home can create a health and re hazard.