*www.novatekco.com * toll free 866.563.7800 * tele 610.363.7800 * fax 610.935.1945 * sal[email protected]*
6
CONTROL DESCRIPTIONS
1. Circuit Breaker Switch
The green circuit breaker switch is used to show power is going to Novair and protect the controls of the
machine. This adds power to the GFCI outlets to allow daisy chaining of equipment and will trip if
maximum amperage is exceeded.
2. Variable Speed Dial
The variable speed dial can be set from 200 -700cfm depending on the desired vacuum flow. The
maximum setting is shown to the left as the dial is first turned to the “ON” position.
3. Auxiliary “GFCI” protected Outlet -115v
The auxiliary GFCI outlet can be used to daisy chain “No More” the 3 units together. The maximum of
12 Amps when the unit is in the “OFF” position and 9 Amps when the unit is in the “ON” position. You
can attach other pieces of equipment to this but are limited to the maximum amp draw. When the outlet
is working properly the green light is lit on circuit breaker.
Auxiliary Outlet -230v (Not Shown)
The auxiliary 230voutlet can be used to daisy chain “No More” the 3 units together. The maximum of 6
Amps when the unit is in the “OFF” position and 4 Amps when the unit is in the “ON” position. You can
attach other pieces of equipment to this but are limited to the maximum amp draw. When the outlet is
working properly the green light is lit on circuit breaker.
CAUTION: If the GFCI trips “UN-PLUG” the unit from the power source and check for any
potential hazards (damaged power cord, moisture, too many units plugged, etc.) causing a
power surge. Once unit is evaluated plug the unit into a new power source and push the reset
button. If unit operates as normal: continue use, if unit trips again contact Novatek at 866-563-
7800.
4. Filter change indicator
The indicator light will alert the operator when filters are loaded or when air flow is greatly decreased.
The light will come on once the pressure reaches approximately 3” of water column. Filters should be
inspected and replaced. Once filters are replaced the light will go off. If light stays on contact Novatek at
866-563-7800.
5. Power Cord
Firmly insert the female end of the power cord into a grounded power source. Visually inspect the cord
for any damage before installation into power source.
CAUTION: A loose, corroded, ill fitted or damaged cord or plug can cause injury. If cord has any
of these issues should be re-placed immediately.