6
Uncoil the power cord and plug it firmly into a properly grounded 110-120 volt AC outlet.
After plugged in, the control panel will be light up for 1-2 seconds and then goes off, which is the
normal self-diagnose process and does not require any user intervention.
3. Turn the Dehumidifier On
Press the POWER button to turn the dehumidifier on. Typically, the dehumidifier will run in the
default setting of 30% set humidity at low fan speed in the normal DEHUMIDIFY mode.
NOTE: If the dehumidifier does not run automatically and you see the FULL icon illuminate, please
remove the water bucket and re-install it properly.
4. Select Working Mode
1) DH (DEHUMIDIFY) Mode
In the DH (DEHUMIDIFY) mode, the dehumidifier will automatically stop and restart based on the
humidity setting, which is called Humidstat Mode, hence maintaining the room humidity within the
range of ±3% of the set point.
For example, the set humidity is 50%, the dehumidifier will automatically stop working when the
room humidity reaches 47%, and then automatically restart when the room humidity raises up to
53%.
NOTE:
When the set humidity level is not at least 3% lower than the room humidity level, the dehumidifier
wont start, and DH icon will flash.
When the room humidity level has been dropped down to the set-point, the dehumidifier will auto
stop dehumidifying and the DH icon will flash.
If you set the target humidity at 30%, the dehumidifier will run continuously until the water bucket
is full, which is called CONTINUOUS Mode.
To run the dehumidifier in the normal DEHUMIDIFY mode:
· Select Mode: Press the MODE button until you see the DH icon light up on the display to select
the normal DEHUMIDIFY mode.
· Check the Room Humidity: when no operation on the control panel, the digital number on the
display is the humidity readout of the inlet air, which is similar to the room humidity level.
· Set Your Desired Humidity: After selecting DEHUMIDIFY mode, press the HUMIDITY button
repeatedly to adjust the set-point of humidity level between 30%-80% in 5% increments. The digital
number will flash when changes are being made. The set humidity needs to be at least 5% lower
than the room humidity. After you have selected the desired value, please wait for 5 seconds until