MAINTENANCE AND CLEANING
 Before cleaning the fan, turn it off and unplug it.
CLEANING THE WATER TANK
 After each use, pour the remaining water out of the tank Aqs and rinse it with clean water.
 Regularly remove lime deposits from the tank Aqs at least once a month. To remove lime deposits,
use a clean cloth and a solution of warm water and neutral detergent. After using the detergent,
rinse the tank Aqs with clean water.
CLEANING THE REMOVABLE FILTERS
 Clean the dust and water fi lters A8, A9 regularly at least once a month. Remove the fi lters and
clean them with a soft brush, using a neutral cleaning agent. Then thoroughly rinse under fl owing
water and allow to dry naturally. After the fi lters have dried, reinstall them.
Caution:
Do not dry the fi lters with a hair dryer or in direct sunlight.
CLEANING THE OUTER CASING
 Wipe the exterior with a clean, dry cloth. For tougher dirt, use a cloth slightly moistened with
a solution of warm water and neutral detergent.
 Do not clean any part of the fan with aggressive substances, petrol or any other solvent.
 If you will not be using the fan for an extended time, store it in a clean, dry place. Remove the
battery from the remote control.
TECHNICAL SPECIFICATIONS
Nominal voltage ..............................................................................................................................220−240 V
Nominal frequency ..................................................................................................................................50 Hz
Rated power input .................................................................................................................................110 W
Safety class (for electric shock protection) ................................................................................................... II
Noise level ...........................................................................................................................................66 dB(A)
Maximum fan fl ow rate ............................................................................................................. 20,81 m³/min
Service value .......................................................................................................................... 0,23 (m³/min)/W
Standby power consumption ..............................................................................................................0,19 W
Maximum air velocity ..........................................................................................................................3,37 m/s
Measurement standard for service value ............................ COMMISSION REGULATION (EU) No 206/2012
IEC 60879:1986, EN 50564:2011,
EN 60704-2-7:1998, EN 60704-1:2010
Contact details for obtaining more information ..............................FAST ČR, a. s., Černokostelecká 1621,
251 01 Říčany, Czech Republic
The declared noise emission level for this appliance is 66 dB(A), which represents level A of the acoustic
power relative to the reference acoustic power of 1 pW.