Whirlpool WVW7336JS0 range hood

User Manual - Page 4

For WVW7336JS0.

PDF File Manual, 15 pages, Download pdf file

Loading ...
Loading ...
Loading ...
4
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting
Tools Needed
Level
Drill with 1
1
/
4
" (3 cm),
3
/
8
5
/
16
Pencil
Wire stripper or utility knife
Tape measure or ruler
Pliers
Caulking gun and weatherproof caulking compound
Vent clamps
Jigsaw or keyhole saw
Flat-blade screwdriver
Metal snips
Phillips screwdriver
Metric hex key set
Parts Needed
Home power supply cable
1
/
2
" (12.7 mm) UL listed or CSA approved strain relief
3 UL listed wire connectors
For Vented Installations, You Will Also Need:
1 wall or roof cap
Metal vent system
For Non-Vented (Recirculating) Installations,
Recirculation Kit. See “Assistance or Service” section to order.
6" (15.2 cm) diameter round metal vent duct -
Parts Supplied
Remove parts from packages. Check that all parts are included.
Hood canopy assembly with ventilator and light bulbs
installed
Vent transition with back draft dampers installed
Vent cover support bracket
Mounting template
2-piece vent cover
2 - 3.5 x 9.5 mm screws
2 - 2.9 x 6.5 mm screws
6 - 5 x 45 mm mounting screws
2 - 8 x 40 mm wall anchors
4 - 10 x 50 mm wall anchors
T20
®
† Torx
®
adapter
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
installer's responsibility to comply with installation clearances
vent hood.
Canopy hood location should be away from strong draft areas,
such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance.
Grounded electrical supply is required. See “Electrical
Requirements” section.
The canopy hood is factory set for venting through the roof
or wall. For non-vented (recirculating) Installation see “For
Nonvented (recirculating) Installations Only” in “Connect Vent
System” section. Recirculation Kit . See “Assistance or Service”
section to order.
NOTE: This product will not comply with Energy Star
the optional recirculation kit.
All openings in ceiling and wall where canopy hood will be
installed must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title
24 CFR, Part 328 (formerly the Federal Standard for Mobile
Home Construction and Safety, Title 24, HUD, Part 280)
or when such standard is not applicable, the standard for
Manufactured Home Installation 1982 (Manufactured Home
Sites, Communities and Setups) ANSI A225.1/NFPA 501A, or
latest edition, or with local codes.
Product Dimensions
* For non-vented (recirculating) installations
** For vented installations
30" (76.2 cm) or
36" (91.4 cm)
10"
(25.4 cm)
20" (50.8 cm)
®
†TORX and T20 are registered trademarks of Acument Intellectual Properties, LLC.
Loading ...
Loading ...
Loading ...