Wolf GR304LP 30 Inch ProStyle Freestanding Gas Range with 4

User Manual - Page 119

For GR304LP.

PDF File Manual, 162 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
wolfappliance.com
|
119
INDUCTION RANGES
BUILT-IN OVENS COOKTOPS | COFFEE RANGES | RANGETOPS OUTDOOR GRILLS VENTILATION
Planning Information
Follow all minimum clearances to combustible surfaces
shown in the illustration on the following page.
IMPORTANT NOTE: Adjacent countertops must be at least
35
7
/8" for ush installation to top of unit.
ELECTRICAL
Installation must comply with all applicable electrical codes.
Locate the electrical supply ush with the wall or oor and
within the shaded area shown in the illustration on the fol-
lowing page. A separate circuit, servicing only this appliance
is required.
If a power supply cord is being used, the cord must be
designated for use with ranges and rated for 240 V, 50
amps (refer to the chart), and must include 3 or 4 conduc-
tors. A 4-conductor cord is required for installations where
grounding through the neutral is prohibited.
Performance may be compromised if the electrical supply is
less than 240 volts.
ELECTRICAL REQUIREMENTS
Electrical Supply grounded, 240 VAC, 60 Hz