INSTALLATION
CLEARANCES
TO NON-COMBUSTIBLE CONSTRUCTION
A minimum of 4” (10 cm) clearance from the back of the grill to non-combustible construction is required
to allow the hood to be opened fully.
TO COMBUSTIBLE CONSTRUCTION
This appliance should NOT be installed over, under or next to unprotected combustible construction. If
your enclosure (island) is combustible, then an insulated jacket manufactured by Hestan is required. See
INSULATED JACKET dimensions below to make allowances in your enclosure for this item. A minimum
clearance to vertical combustible material is 12” (30 cm) on the sides and the rear of the appliance.
The minimum vertical clearance to combustible materials means that ALL combustible materials must be
outside this 12” (30 cm) zone. As an example, if you have an island with a stucco or tiled surface and wood-
frame construction beneath, the wood is considered combustible, even though the grill is touching the
stucco or tile surface, which is non-combustible. In extreme circumstances, the wood could potentially get
hot enough to burn.
VENTILATION OPENINGS
A minimum of three 10 in² (65 cm²) of ventilation openings must be provided for both left and right sides
of your enclosure (island), as well as the back. These openings are required to safely dissipate gas vapors if
there is a leak in your enclosure.
BUILT-IN DIMENSIONS