SSTB11 Woodburning Fireplace
FLOOR PROTECTION
If this replace is installed on a combustible oor, the oor area 16 inches in front of, and 8 inches either side of the
replace opening must be protected by an insulating noncombustible hearth extension. Figure 8
With either type hearth extension minor shifting of the supporting oor or expansion and contraction may eventually
cause a crack to develop between the hearth extension and the face of the replace. To help prevent the crack from
developing, the hearth extension materials must be rmly fastened in place. Wall ties should be screwed to the face
of the replace and imbedded in the mortar joints of brick, stone, or other non-combustible materials. The metal safety
strip packed with the replace must be placed beneath the replace and extended under the hearth extension or into
a mortar joint of the hearth extension as shown by Figure 9. In the event a crack does eventually develop, the metal
safety strip will serve as a barrier to prevent sparks or embers from falling from the replace onto combustible ooring
materials.
&0
FIREPLACELOCATION
16”
3/4”
26M” Min.
60”
3/4”
8”
Model H165
Hearth Extension
Model H165
Hearth Extension
Parallel
Back Wall
Perpendicular
Side Wall
Side Brick Outline
Glass Door
Glass Door
Min. Air
Space
Min. Air Space
FP179
Figure 8
NOTE: If noncombustible hearth extension materials are to be
placed at or below the level of the bottom of the replace, insu-
lation board is not required.
If the replace is recessed into the oor or the hearth is elevat-
ed with combustible materials, an MHSC H165 hearth exten-
sion kit or equivalent must be used for additional protection.
&0
SAFETYSTRIP
Metal Safety
Strip
( Required)
”
”
”
Special ‘Z’ Metal
Safety Strip
( Required)
FP183
Figure 9