Champion Power Equipment 100719 8500-Watt Portable Inverter Generator, Electric Start and CO Shield

OPERATOR’S MANUAL - Page 26

For 100719.

PDF File Manual, 41 pages, Read Online | Download pdf file

100719 photo
Loading ...
Loading ...
Loading ...
100719 - 8500W ELECTRIC START INVERTER GENERATOR
OPERATION
26
2. Press the “TEST” (C) button located on the front of the
receptacle to trip the device. This should immediately stop
the flow of electricity and shut off the lamp. If the electricity
is not stopped, do not use this receptacle until it has been
serviced or replaced.
3. Press the “RESET” button located on the front of the
receptacle to restore the flow of electricity. If the indicator
light does not come back on or if the GFCI cannot be reset
then it must be replaced.
B
C
A
NOTICE
In any electrical application, some current will flow through
the protective ground conductor to the ground, this is called
leakage current. It takes 4 mA (0.004 A) and higher of leakage
current from the hot wire to the ground to cause a GFCI to trip.
On circuits protected by GFCI’s, leakage current can cause
unnecessary and intermittent tripping.
Some stationary motors, such as a bathroom vent fan,
fluorescent lighting fixtures or some refrigerators, may produce
enough leakage to cause nuisance tripping. To avoid nuisance
tripping, a GFCI should not supply:
Fluorescent or other types of electric-discharge lighting
fixtures.
Permanently installed electric motors, like air conditioners,
furnaces or refrigerators.
Eco (Economy) Mode
The Eco Mode button can be activated to turn on economy control
in order to minimize fuel consumption and noise while operating
the unit during times of reduced electrical output. Eco Mode
allows the engine speed to idle during periods of non-use.
The engine speed returns to normal when an electrical load is
connected. When the economy switch is off, the engine runs at
normal speed continuously.
CAUTION
For periods of high electrical load or momentary fluctuations,
the Eco Mode should be off.
12V DC Regulated Automotive Style Outlet
The 12V DC outlet(s) can be used with supplied accessories and
other commercially available 12V DC automotive style plugs.
Confirm the input voltage range of your item is at least 12-24V DC.
WARNING
When charging a device, do not place on the exhaust side of
the generator. Extreme heat caused by exhaust can damage
the device and cause a potential fire hazard. Prolonged
exposure to engine exhaust can cause serious injury or death.
Battery Charging
1. Before connecting the battery charging cable (not included) to
a battery that is installed in a vehicle, disconnect the vehicle
battery ground cable from the negative (–) battery terminal.
2. Plug the battery charging cable into the 12V DC receptacle of
the generator.
3. Connect the red (+) battery charger lead to the red (+) battery
terminal.
4. Connect the black (–) battery charger lead to the black (–)
battery terminal.
5. Start the generator.
Important: The 12V DC outlet is ONLY to be used with supplied
accessories and other commercially available 12V DC automotive
Loading ...
Loading ...