100719 - 8500W ELECTRIC START INVERTER GENERATOR
OPERATION
24
3. Remove the oil drain side maintenance cover by pushing and
turning the two fasteners counterclockwise to the unlocked
horizontal position.
4. Pull the recoil cord slowly until resistance is felt and then pull
rapidly.
5. Do not over-choke. As soon as engine starts, turn the EZ
Start dial to the “RUN” position.
6. Re-install the maintenance cover.
NOTICE
For gasoline restarts with hot engine in hot ambient
temperature >86°F (30°C): Rotate the EZ Start dial to
the “CHOKE” position for only one pull of the recoil cord. If
generator does not start after first pull, rotate the dial to the
“RUN” position for the next three pulls. Too much choke leads
to spark plug fouling and engine flooding. This will cause the
engine not to start.
NOTICE
For gasoline starting in standard ambient temperature
>59°F (15°C): Keep EZ Start dial in “CHOKE” position for three
pulls of the recoil cord. If generator does not start after three
pulls, rotate the EZ Start dial to the “RUN” position for the next
three pulls. Too much choke leads to spark plug fouling and
engine flooding. This will cause the engine not to start.
NOTICE
For gasoline starting in cold ambient temperature < 59°F
(15°C): Keep the EZ Start dial in the “CHOKE” position until
engine starts. As soon as the engine starts and runs smoothly
turn the EZ Start dial to the “RUN” position. In extreme cold
temperatures, this may take several seconds.
NOTICE
If the engine starts but does not continue to run make certain
that the generator is on a flat, level surface. The engine is
equipped with a low oil sensor that will prevent the engine
from running when the oil level falls below a critical threshold.
Connecting Electrical Loads
Let the engine stabilize and warm up for a few minutes after
starting.
Plug in and turn on the desired 120 or 240 (if applicable) Volt AC
single phase, 60 Hz electrical loads.
DO NOT connect 3-phase loads to the generator.
DO NOT overload the generator.
Use only a high quality, insulated, compatible (3-wire or
4-wire) grounded cord set rated equal to or greater (volts and
amps) than the receptacle plugging into.