INSTALLATION
¼êÐ|ŒêĒĉ
www.stiebel-eltron-usa.com CK 150-1 / 200-2 Trend | 9
ENGLISH
NOTE:
The dust filter is 10
7
/
8
˝ (27.5cm) wide.
To enable removal of the dust filter as described (See
6, “Cleaning, care and maintenance”, pg. 4), main-
tain a sufficiently large clearance at the side.
If you have installed the heater in a recess, detach the
heater from the wall mounting bracket before remov-
ing the dust filter.
WARNING: Fire
Combustible materials such as furniture, papers,
clothes and curtains must be kept at least 3 feet (0.9 m)
from the heater.
Never place any flammable, combustible or insulating
objects or materials, such as laundry, blankets, maga-
zines, containers with floor polish or gasoline, spray
cans or similar on the heater or in direct proximity to
it.
14.3 Data table
CK 150-1 Trend CK 200-2 Trend
Part number 236304 236305
Electrical data
Phase/Frequency 1 - 60 Hz
Heating Capacity 1500 W 2000 W 1800 W
Rated voltage 120 V 240 V 208 V
Amperage 12.5 A 8.3 A 8.7 A
Required wire size (copper) 14 AWG 14 AWG
Dimensions
Height 15¾˝ (40.0 cm)
Width 10
7
/
8
˝
(27.5 cm)
Depth 5
1
/
8
˝ (13.1 cm)
Weights
Weight 5.5 lbs (2.5 kg)
Miscellaneous
Frost protection setting 45°F (7°C)
Color Traffic white, RAL 9016
Setting range 45–95 °F (7–35 °C)
Operating noise 49 dB(A)
14.4 Wiring diagram CK 150-1 Trend
NL
M
~1
H1
H2
M1
A1
F1
N1
X1
S1
A1 Heating element assembly
F1 High temperature limiter
H1 Fusible link
H2 Fusible link
M1 Fan motor
N1 Thermostat
S1 On/off switch
X1 Wiring block
14.5 Wiring diagram CK 200-2 Trend
LL
M
~1
H1
H2
M1
A1
F1
S1
N1
X1
A1 Heating element assembly
F1 High temperature limiter
H1 Fusible link
H2 Fusible link
M1 Fan motor
N1 Thermostat
S1 On/off switch
X1 Wiring block