Kenmore 58075119700 air conditioner

User Manual - Page 5

For 58075119700.

PDF File Manual, 36 pages, Download pdf file

Loading ...
Loading ...
Loading ...
-5-
ENGLISH
INSTALLATION
INSTALLATION REQUIREMENTS
If you use an existing wall sleeve, you should
measure its dimensions.
Install the new air conditioner according to these
installation instructions to achieve the best
performance. All wall sleeves used to mount the
new air conditioner must be in good structural
condition and have a rear grille to securely attach
the new air conditioner. (FIG. 1)
With the Kenmore folding sleeve,youcan
maintain the best performance of the new air
conditioner.
ELECTRICAL SERVICE
Check your available electrical service. The power
supply available must be the same as that shown
on the unit nameplate (found on left side of cabinet).
All models are equipped with a 3-prong service plug
to provide proper service and safe positive
grounding. Do not change plug in any way. Do not
use an adapter plug. If your present wall outlet does
not match your plug, call a qualified electrician to
make the necessary corrections. SAVE CARTON
for storage and this OWNER'S MANUAL for future
reference. The carton is the best way to store unit
during winter or when not in use.
INSTALLATION HARDWARE
14-
13
/
32
"
(366 mm)
24-
21
/
32
"
(626 mm)
18"(458 mm)
19-
21
/
32
"
(499 mm)
1
4
5
6
7
3
2
8
2 Size options
2 Size options
To avoid risk of personal injury, property damage,
or product damage due to the weight of this
device and sharp edges that may be exposed:
Air conditioners covered in this manual pose an
excessive weight hazard. Two or more people
are needed to move and install the unit.
To prevent injury or strain, use proper lifting and
carrying techniques when moving unit.
Carefully inspect location where air conditioner
will be installed. Be sure it will support the weight
of the unit over an extended period of time.
Handle air conditioner with care. Wear
protective gloves whenever lifting or carrying the
unit. AVOID the sharp metal fins of front and
rear coils.
Make sure air conditioner does not fall during
installation.
CAUTION
REQUIRED TOOLS:
Tight Fitting gloves
Standard screwdriver
Phillips screwdriver
Pliers
Sharp knife
3/8-inch open end
wrench or adjustable
wrench
1/4-inch hex socket
and ratchet
Tape measure
Electric drill
1/4-inch drill bit
FIG. 1
Air Conditioner
ITEM NAME OF PARTS Q'TY
1 PLASTIC GRILLE 1
2 HORIZONTAL INSULATION STRIPS 2
3 AROUND INSULATION STRIPS 2
4 SUPPORT BLOCK 2
5BAFFLE 1
6 TRIM FRAME 2
7SHIM 2
8
PLASTIC NUTS AND WASHER SCREWS
4
Loading ...
Loading ...
Loading ...