Drain Pump Mounting Tab Slot
Drain Pump Installed
8. Align the 2 screw holes at the rear of the pump. Use two
#8-32 x ³⁄₈" screws, supplied. See “Parts Locations”
illustration.
9. Connect drain tube to ice maker bin outlet (⁵⁄₈" I.D.), using
⁷⁄₈" adjustable clamp, supplied. See “Drain Tube” illustration.
10. Coil ice maker power cord into a 4" (10.2 cm) diameter coil.
Wrap electrical tape around the power cord in several places
to keep the cord in a coil. Locate coiled power cord between
the drain pump and side of enclosure and plug into the
receptacle of the drain pump. See “Parts Locations”
illustration.
11. Attach the drain pump power cord to ice maker unit base with
clamp and screw (removed in Step 6) that was used to attach
ice maker power cord. See “Parts Locations” illustration.
12. Place new rear panel (small one for 15" ice makers, large one
for 18") against the back of the ice maker. Route the vent
tube and drain pump discharge tube through cutouts in the
rear panel.
13. Secure rear panel with original screws. See “Rear Panel”
illustration.
14. Secure vent tube to back of ice maker using 3 clamps
and three #8-32 x ³⁄₈" screws, supplied. See “Vent Tube”
illustration.
Vent Tube
NOTE: Do not pinch, kink, or damage the vent tube. Check that it
is not damaged, pinched, or kinked between the cabinet and the
ice maker.
15. Attach ¹⁄₂" I.D. x 10 ft (3 m) drain tube to pump discharge
tube. See “Parts Locations” illustration.
NOTE: Do not connect outlet end of drain tube to a closed
pipe system to keep drain water from backing up into the
ice maker.
16. Connect ice maker to water supply and install ice maker
as specified by the product installation instructions.
17. Check all connections for leaks.
18. Plug in ice maker or reconnect power.
19. Turn on ice maker.
20. Wait for rinsing cycle, approximately 5 minutes, to be sure the
ice maker is operating properly.
A. Mounting tab slot
A. Drain pump installed
A
A
A. Vent tube
B. Clamps and screws
A
B
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.