ELECTRIC DRYER UNITS
GROUNDING INSTRUCTIONS
This electric dryer must be connected to a ground metal, permanent wiring system; or an
equipment grounding conductor must be run with the circuit conductors and connected to the
equipment grounding terminal on the back panel.
Electric models are shipped with a ground strap connected from the neutral (P2) terminal
block post to the frame of the dryer. The use of this strap is permitted by the national elec-
trical code. The dryer electrical supply may be connected by means of a new U.L. Listed
power supply cord kit rated at 240 volts minimum, 30 amperes with three No. 10 copper
wire conductors terminated with closed loop terminals, open end spade lugs with turned up
ends or with tinned leads.
Pt" P2 -P3
Strain Relief
f"
The power cord must be marked for use with a clothes dryer and be retained with suitable
strain relief. If the dryer is to be installed in a mobile home or an area where local codes do
not permit grounding through neutral, only a 4 conductor power cord, rated and terminated
as above, may be used.
The electrical supply circuit should be fused through a 30 amp fuse or circuit breaker on both
sides of the line. The neutral line of the service cord must always be connected to the P2
terminal post. The two hot lines of the service cord go to the PI and P3 terminal block
posts. The neutral should not be fused or broken. Be sure terminal block nuts are tight and
replace access cover.
Canadian models are shipped with approved power cord sets attached.