Richmond RMTEX-06 Essential 5.5 kW Tankless Electric Water Heater

User Manual - Page 7

For RMTEX-06.

PDF File Manual, 36 pages, Read Online | Download pdf file

RMTEX-06 photo
Loading ...
Loading ...
Loading ...
Electrical Specifications by Heater Input
HEATER INPUT
8kW
11kW
13kW
18kW
24kW
27kW
36kW
ELEMENTS
1
2
2
2
3
3
4
VOLTAGE
240 V
240 V
240 V
240 V
240 V
240 V
240 V
MAX kW
8 kW
11 kW
13 kW
18 kW
24 kW
27 kW
36 kW
kW PER ELEMENT
8 kW
5.5 kW
6.5 kW
9 kW
8 kW
9 kW
9 KW
MAX AMPERAGE DRAW
33 AMPS
46 AMPS
54 AMPS
75 AMPS
100 AMPS
112.5 AMPS
150 AMPS
REQUIRED BREAKERS
1 x 40 AMP
1 X 60 AMP
1 X 60 AMP
2 X 40 AMP
3 x 40 AMP
3 X 40 AMP
4 X 40 AMP
REQUIRED WIRE GAUGE
1 x 8 AWG
1 x 6 AWG
1 x 6 AWG
2 X 8 AWG
3 x 8 AWG
3 X 8 AWG
4 X 8 AWG
Wiring Diagram
8kW, 11kW, 13kW heaters
require 1 set of breaker and wire
18kW heater requires 2 sets of breakers and wires
24kW and 27kW heaters require 3 sets of breakers and wires
36kW heater requires 4 sets of breakers and wires
L1
L2
L2
L2
L2
L1
L1
L1
Loading ...
Loading ...
Loading ...