Richmond RMTEX-06 Essential 5.5 kW Tankless Electric Water Heater

User Manual - Page 11

For RMTEX-06.

PDF File Manual, 36 pages, Read Online | Download pdf file

RMTEX-06 photo
Loading ...
Loading ...
Loading ...
10
10- USER INTERFACE
Power
Click adjustment knob, the display will turn on
Click the adjustment knob again, the display will turn off
C/F Conversion
Press the adjustment knob for 3 seconds, the display will change from Fahrenheit to Celsius or vice
versa
Temperature Control
Turning the knob clockwise increases the set output water temperature
Turning the knob counter clockwise decreases the set output water temperature
You can set or adjust the temperature at any time between 80°F 140°F (27°C 60°C). The temperature
can be changed to your desired setting. The display will only stay on when the unit is in use or when you
are setting the temperature.
DANGER Hotter water increases the potential for Hot Water SCALDS
CAUTION removing the cover to change the temperature set point exposes electrical shock and burn hazards,
which can cause INJURY or DEATH. Adjustment should only be done by a licensed plumber or electrician.
Heater input: 8kW 11kW 13kW Heater input: 18kW 24kW 27kW 36kW
1. Hot Water Outlet
5. Adjustment Knob & Temperature Control
9. Electrical Strain Relief
2. Cold Water Inlet
6. Wire Connection
10. Mounting Bracket (1”)
3. Celsius/Fahrenheit Conversion (Press & Hold 3 sec.)
7. Brass Compression Nut
4. Temperature Set Point Display
8. Brass Compression Ferrule
Input
Height in(mm)
Width in(mm)
Depth in(mm)
8/11/13kW
12 (292.1)
9.75 (247.7)
3.75 (95.3)
18kW
18 (431.8)
14 (355.6)
3.75 (95.3)
24/27kW
18 (431.8)
17 (431.8)
3.75 (95.3)
36kW
18 (431.8)
19 (482.6)
3.75 (95.3)
Loading ...
Loading ...
Loading ...