7.2. Settings
You can customize the working mode of AC300+B300 and tweak the
parameters such as language, voltage, frequency, current (UPS In-Grid Mode),
working type, date/time, etc.
Click the Settings Button in the homepage to enter the setting interface.
7.2.1. AC Output Voltage & Frequency
NOTE: Please check the output voltage, frequency, and other parameters
BEFORE using for the rst time. The AC300 100-120V AC version cannot be
set to 220-240V AC output. Users can tap the screen to set the parameters as
needed. Output frequency and voltage can only be tweaked when the AC is
OFF (tap the AC icon at homepage to turn o AC output).
The list of standard output voltage and frequency in 5 regions or countries.
JP Output: 100V/50 or 60Hz
US Output: 120V/60Hz
AU Output: 240V/50Hz
EU/UK Output: 230V/50Hz
7.2.2. DC Input Source
DC Input Source: AC300 integrates dual MPPT and separates the DC input
source into DC1 and DC2 in parallel. DC1 indicates the first group of DC
input source as the labels written on MC4 plug of PV charging cables:
DC1 PV+ and DC1 PV-, DC2 PV+ and DC2 PV-.
DC1/DC2 consist of both positive pole and negative pole of the MC4 plugs.
Both DC1 and DC2 input source can be set on touchscreen: (Mainpage -
Settings - DC1/DC2 Input Source).