Adcraft VS-300 Vacuum Packaging Machine

INSTRUCTION MANUAL - Page 5

For VS-300.

PDF File Manual, 10 pages, Read Online | Download pdf file

VS-300 photo
Loading ...
Loading ...
Loading ...
October 2016
Adjusting the Timing Controls
NOTE:All timing adjustments must be made with the lid lock off and the lid open.
To adjust or set the timing controls, press the SET button on the control panel until the required
label (Vacuum, Sealing or Cooling) is illuminated. For each selection, the current time setting will
show on the LED screen. All time settings are dsplayed in seconds.
For initial testing, the time settings should be:
Vacuum time - 40 seconds
Sealing time - 1.2 seconds
Cooling time - 2 seconds
Vacuum Time: To increase or decrease the vacuum time, press the SET button until VACCUM is
illuminated and then use the UP/DOWN buttons to adjust the vacuum time accordingly. The time
setting will display on the LED screen on the control panel.
NOTE:llerplatescanbeusedtoreducethevacuumtimerequired.Placethellerplates
inside the chamber as desired.
Sealing Time: To increase or decrease the sealing time, press the SET button until SEALING is
illuminated and then use the UP/DOWN buttons to adjust the sealing time to accommodate your
application. It is recommended that you make adjustments in 0.1 second increments to avoid
melting the pouch.
Note: for thicker pouches, you should increase the seal time in 0.1 increments until the
pouch seals completely. For thinner pouches, decrease the seal time in 0.1 increments to avoid
over sealing the pouch
Cooling Time: To increase or decrease the cooling time, press the SET button until COOLING is il-
luminated and then use the UP/DOWN buttons to adjust the cooling time accordingly.
NOTE: to prolong the life of your seal bar, set the cooling time to twice the sealing time.
Loading ...
Loading ...
Loading ...